Condition monitoring of polymer electrolyte membrane fuel cells

dc.contributor.advisorBarendse, Paul Stanleyen_ZA
dc.contributor.advisorPillay, Pragasenen_ZA
dc.contributor.authorDe Beer, Chrisen_ZA
dc.date.accessioned2015-07-02T08:28:14Z
dc.date.available2015-07-02T08:28:14Z
dc.date.issued2014en_ZA
dc.descriptionIncludes bibliographical references.en_ZA
dc.description.abstractAs the global demand for energy continues to grow new technologies and systems must be developed to supply the market. This includes renewable energy generation, storage and conversion systems. The primary storage technology in use today in the portable electronics, the automotive sector and to a lesser extent power networks is battery based systems. To overcome some of the limitations inherent in batteries, fuel cell based power generators and converters have been developed. Fuel cells act as electrochemical energy converters that convert a fuel source such as natural gas directly into electrical power without any secondary phases. For systems running on Hydrogen generated via renewable or natural sources, the input/output cycle becomes completely sustainable. Out of the different fuel cell types available and under development, the Proton Exchange Membrane or Polymer Electrolyte Membrane (PEM) fuel cell has emerged as the technology of choice, and currently owns more than 80% of the commercial fuel cell market. This has spurred further research in the field to increase performance and life expectancy of the cell materials. A promising development in the form of High Temperature PEM (HT-PEM) fuel cells has recently emerged and addresses some of the shortcomings of the low temperature counterparts. A critical field of research is the condition monitoring strategies and technologies for the electrochemical device that ties in with the power conditioning sub-systems. This thesis presents the development of condition monitoring systems by conducting detailed studies on the fault/degradation mechanisms prevalent in the cell materials for the purpose of detection, classification and implementation of possible mitigation strategies. Specific consideration is given to the detailed analysis of the fault mechanisms in HT-PEM fuel cells that are not yet fully understood and commercialized. In particular, electrochemical equivalent circuit models and reduced order semi- empirical models are developed to facilitate fault detection. Based on these models, mitigation strategies for specific faults are proposed and experimentally verified. New systems and methods are developed for rapid online impedance signature mapping that provide a basis for early fault prediction that can increase system performance and life expectancy. The findings in this research provide valuable insight into the effect that most prevalent faults have on the internal electrochemistry and the impact on electrical performance. From the experimental results, a semi-empirical electrochemical model is developed to assist with life time estimation and system optimization. The model is integrated with a real time emulator platform that can reproduce single cell voltage levels at the high output currents and transient characteristics. A detailed analysis is conducted on CO poisoning and the resulting effects on key equivalent circuit parameters that enable quantification of the fault condition. It is shown that the catalyst at the higher operating temperature is still susceptible to a certain degree of semi-permanent degradation. To mitigate these effects, a new active current control strategy is proposed to enforce electro-oxidation of the CO to recover the lost active area that delivered superior results compared to current pulsing strategies. New rapid online detection strategies are proposed by using small voltage transients in an operational HT-PEM fuel cell. The method makes use of the discrete S-transform that overcomes some of the limits in other signal processing methods used in fuel cell diagnostics. To enable detailed parameter calculation, a population based incremental learning algorithm is implemented in the developed method. A new condition monitoring system is developed that makes use of Optimized Broadband Impedance Spectroscopy. The hardware is designed to accommodate both single cell and stack level implementation. It is shown that the proposed system is able to deliver measurements under extreme non-linear conditions that can occur in PEM fuel cells in a fraction of the time associated with normal EIS based systems.en_ZA
dc.identifier.apacitationDe Beer, C. (2014). <i>Condition monitoring of polymer electrolyte membrane fuel cells</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering. Retrieved from http://hdl.handle.net/11427/13264en_ZA
dc.identifier.chicagocitationDe Beer, Chris. <i>"Condition monitoring of polymer electrolyte membrane fuel cells."</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2014. http://hdl.handle.net/11427/13264en_ZA
dc.identifier.citationDe Beer, C. 2014. Condition monitoring of polymer electrolyte membrane fuel cells. University of Cape Town.en_ZA
dc.identifier.ris TY - Thesis / Dissertation AU - De Beer, Chris AB - As the global demand for energy continues to grow new technologies and systems must be developed to supply the market. This includes renewable energy generation, storage and conversion systems. The primary storage technology in use today in the portable electronics, the automotive sector and to a lesser extent power networks is battery based systems. To overcome some of the limitations inherent in batteries, fuel cell based power generators and converters have been developed. Fuel cells act as electrochemical energy converters that convert a fuel source such as natural gas directly into electrical power without any secondary phases. For systems running on Hydrogen generated via renewable or natural sources, the input/output cycle becomes completely sustainable. Out of the different fuel cell types available and under development, the Proton Exchange Membrane or Polymer Electrolyte Membrane (PEM) fuel cell has emerged as the technology of choice, and currently owns more than 80% of the commercial fuel cell market. This has spurred further research in the field to increase performance and life expectancy of the cell materials. A promising development in the form of High Temperature PEM (HT-PEM) fuel cells has recently emerged and addresses some of the shortcomings of the low temperature counterparts. A critical field of research is the condition monitoring strategies and technologies for the electrochemical device that ties in with the power conditioning sub-systems. This thesis presents the development of condition monitoring systems by conducting detailed studies on the fault/degradation mechanisms prevalent in the cell materials for the purpose of detection, classification and implementation of possible mitigation strategies. Specific consideration is given to the detailed analysis of the fault mechanisms in HT-PEM fuel cells that are not yet fully understood and commercialized. In particular, electrochemical equivalent circuit models and reduced order semi- empirical models are developed to facilitate fault detection. Based on these models, mitigation strategies for specific faults are proposed and experimentally verified. New systems and methods are developed for rapid online impedance signature mapping that provide a basis for early fault prediction that can increase system performance and life expectancy. The findings in this research provide valuable insight into the effect that most prevalent faults have on the internal electrochemistry and the impact on electrical performance. From the experimental results, a semi-empirical electrochemical model is developed to assist with life time estimation and system optimization. The model is integrated with a real time emulator platform that can reproduce single cell voltage levels at the high output currents and transient characteristics. A detailed analysis is conducted on CO poisoning and the resulting effects on key equivalent circuit parameters that enable quantification of the fault condition. It is shown that the catalyst at the higher operating temperature is still susceptible to a certain degree of semi-permanent degradation. To mitigate these effects, a new active current control strategy is proposed to enforce electro-oxidation of the CO to recover the lost active area that delivered superior results compared to current pulsing strategies. New rapid online detection strategies are proposed by using small voltage transients in an operational HT-PEM fuel cell. The method makes use of the discrete S-transform that overcomes some of the limits in other signal processing methods used in fuel cell diagnostics. To enable detailed parameter calculation, a population based incremental learning algorithm is implemented in the developed method. A new condition monitoring system is developed that makes use of Optimized Broadband Impedance Spectroscopy. The hardware is designed to accommodate both single cell and stack level implementation. It is shown that the proposed system is able to deliver measurements under extreme non-linear conditions that can occur in PEM fuel cells in a fraction of the time associated with normal EIS based systems. DA - 2014 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2014 T1 - Condition monitoring of polymer electrolyte membrane fuel cells TI - Condition monitoring of polymer electrolyte membrane fuel cells UR - http://hdl.handle.net/11427/13264 ER - en_ZA
dc.identifier.urihttp://hdl.handle.net/11427/13264
dc.identifier.vancouvercitationDe Beer C. Condition monitoring of polymer electrolyte membrane fuel cells. [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2014 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/13264en_ZA
dc.language.isoengen_ZA
dc.publisher.departmentDepartment of Electrical Engineeringen_ZA
dc.publisher.facultyFaculty of Engineering and the Built Environment
dc.publisher.institutionUniversity of Cape Town
dc.subject.otherElectrical Engineeringen_ZA
dc.titleCondition monitoring of polymer electrolyte membrane fuel cellsen_ZA
dc.typeDoctoral Thesis
dc.type.qualificationlevelDoctoral
dc.type.qualificationnamePhDen_ZA
uct.type.filetypeText
uct.type.filetypeImage
uct.type.publicationResearchen_ZA
uct.type.resourceThesisen_ZA
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
thesis_ebe_2014_debeer_c.pdf
Size:
2.49 MB
Format:
Adobe Portable Document Format
Description:
Collections