The development of a test rig to determine fouling factors of feedwater heaters

dc.contributor.advisorFuls, Wim
dc.contributor.authorHallatt, Nicolaas
dc.date.accessioned2020-05-05T11:09:30Z
dc.date.available2020-05-05T11:09:30Z
dc.date.issued2019
dc.date.updated2020-05-04T08:26:51Z
dc.description.abstractFeed water heaters are large shell and tube heat exchangers. They from part of the Rankine cycle used in coal fired power plants with the main purpose being the improvement of the overall cycle efficiency. Like most heat exchangers, feed water heaters suffer from fouling. Fouling is defined as “any undesirable deposit on heat exchanger surfaces that increases resistance to heat transmission”. In the design of heat exchangers, fouling is accommodated by adding additional surface area to the heat exchanger. The amount of additional area is determined by the use of fouling factors. Although this is the only wide-spread method accepted in industry, the fouling factors in use are outdated, generally considered conservative and lead to oversized heat exchangers. The purpose of this study was to design and build a test rig that can accurately measure fouling factors of feed water heater tubes that has been in service for a full life cycle. A comprehensive literature study was performed to decide on the most effective test method, as well as the required instrument type and accuracy. The best method was found to be where the overall heat transfer coefficient for a fouled tube, outside cleaned tube (half clean) and clean tube was measured. The measured values are then converted to the internal, external and overall fouling factors. Validation test were done on the test rig. These included energy balance tests, theoretical comparison tests and repeatability tests. The results of all tests were acceptable and within measurement uncertainty limits. Five sample test tubes, obtained from a 30 year old LP heater at an Eskom power station, were tested. The results indicated that the average measured fouling factors were less than 20% of the commonly used HEI fouling factors. This is significantly lower and confirms that the fouling factors in use for this specific case are conservative. The test rig proved to be accurate and effective in measuring the fouling factors. Although the tests shows promising results, the small amount of tubes tested from only one heat exchanger are not sufficient to make meaningful conclusions. The test rig is now ready for a future study where a large sample of tubes can be tested.
dc.identifier.apacitationHallatt, N. (2019). <i>The development of a test rig to determine fouling factors of feedwater heaters</i>. (). ,Engineering and the Built Environment ,Department of Mechanical Engineering. Retrieved from en_ZA
dc.identifier.chicagocitationHallatt, Nicolaas. <i>"The development of a test rig to determine fouling factors of feedwater heaters."</i> ., ,Engineering and the Built Environment ,Department of Mechanical Engineering, 2019. en_ZA
dc.identifier.citationHallatt, N. 2019. The development of a test rig to determine fouling factors of feedwater heaters. . ,Engineering and the Built Environment ,Department of Mechanical Engineering. en_ZA
dc.identifier.ris TY - Thesis / Dissertation AU - Hallatt, Nicolaas AB - Feed water heaters are large shell and tube heat exchangers. They from part of the Rankine cycle used in coal fired power plants with the main purpose being the improvement of the overall cycle efficiency. Like most heat exchangers, feed water heaters suffer from fouling. Fouling is defined as “any undesirable deposit on heat exchanger surfaces that increases resistance to heat transmission”. In the design of heat exchangers, fouling is accommodated by adding additional surface area to the heat exchanger. The amount of additional area is determined by the use of fouling factors. Although this is the only wide-spread method accepted in industry, the fouling factors in use are outdated, generally considered conservative and lead to oversized heat exchangers. The purpose of this study was to design and build a test rig that can accurately measure fouling factors of feed water heater tubes that has been in service for a full life cycle. A comprehensive literature study was performed to decide on the most effective test method, as well as the required instrument type and accuracy. The best method was found to be where the overall heat transfer coefficient for a fouled tube, outside cleaned tube (half clean) and clean tube was measured. The measured values are then converted to the internal, external and overall fouling factors. Validation test were done on the test rig. These included energy balance tests, theoretical comparison tests and repeatability tests. The results of all tests were acceptable and within measurement uncertainty limits. Five sample test tubes, obtained from a 30 year old LP heater at an Eskom power station, were tested. The results indicated that the average measured fouling factors were less than 20% of the commonly used HEI fouling factors. This is significantly lower and confirms that the fouling factors in use for this specific case are conservative. The test rig proved to be accurate and effective in measuring the fouling factors. Although the tests shows promising results, the small amount of tubes tested from only one heat exchanger are not sufficient to make meaningful conclusions. The test rig is now ready for a future study where a large sample of tubes can be tested. DA - 2019 DB - OpenUCT DP - University of Cape Town KW - Feedwater Heater KW - Fouling Factors KW - Test Rig LK - https://open.uct.ac.za PY - 2019 T1 - The development of a test rig to determine fouling factors of feedwater heaters TI - The development of a test rig to determine fouling factors of feedwater heaters UR - ER - en_ZA
dc.identifier.urihttps://hdl.handle.net/11427/31774
dc.identifier.vancouvercitationHallatt N. The development of a test rig to determine fouling factors of feedwater heaters. []. ,Engineering and the Built Environment ,Department of Mechanical Engineering, 2019 [cited yyyy month dd]. Available from: en_ZA
dc.language.rfc3066eng
dc.publisher.departmentDepartment of Mechanical Engineering
dc.publisher.facultyFaculty of Engineering and the Built Environment
dc.subjectFeedwater Heater
dc.subjectFouling Factors
dc.subjectTest Rig
dc.titleThe development of a test rig to determine fouling factors of feedwater heaters
dc.typeMaster Thesis
dc.type.qualificationlevelMasters
dc.type.qualificationnameMSc
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
thesis_ebe_2019_hallatt_nicolaas.pdf
Size:
10.86 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
0 B
Format:
Item-specific license agreed upon to submission
Description:
Collections