dc.description.abstractSleep apnoea is the repeated cessation of breathing during sleep and can result in impaired concentration, excessive unexplained sleepiness, and sleep fragmentation. Long-term effects of the condition can include hypertension, stroke and cardiovascular disease, diabetes and glucose intolerance, and obesity. Sleep apnoea is linked to a hazard ratio of 1.97, indicating that individuals with this condition face almost twice the risk of experiencing a stroke or death compared to those without sleep apnoea. It is estimated that 425 million adults between the ages of 30 and 69 have moderate to severe sleep apnoea. A study conducted in Wisconsin, America, found that 82% of men and 93% of women with moderate to severe sleep apnoea had not been diagnosed. This is likely to be even higher in low-middle-income countries like South Africa, where there is limited access to healthcare. Limited access to healthcare also affects sleep apnoea treatment. A study conducted in Latin America found that of the 880 patients diagnosed with sleep apnoea, only 55.7% started Positive Airway Pressure (PAP) therapy, as many of the study participants could not afford a basic level of treatment. This study describes the development of a device that could reduce the prevalence of undiagnosed sleep apnoea cases and improve access to treatment. The developed system makes use of standard breathing effort and pulse oximetry sensors as well as a flow sensor to provide the necessary information to conduct a home sleep test for the diagnosis of sleep apnoea, as required by the American Academy of Sleep Medicine (AASM). The diagnostic algorithm proposed by the AASM is also used to identify apnoea events and present this information to a clinician. The system also provides a basic level of Continuous Positive Airway Pressure (CPAP) treatment, the most common treatment modality used for patients with sleep apnoea. The system performance specifications are tested according to the EN ISO 80601-2-70 testing protocol for the mean static pressure, dynamic pressure accuracy, and maximum flow rate. The ISO standard does not dictate minimum performance requirements; however, the device meets most of the requirements dictated by the Association for Respiratory Technology and Physiology (ARTP), except the requirements for the dynamic pressure accuracy where the device exceeded the maximum pressure range by 1.69cmH2O. The study has demonstrated that a single device could be used to address the high prevalence of undiagnosed and untreated sleep apnoea and thereby prevent associated health risks. Using a single device for the diagnosis and treatment of the condition may also allow clinicians to monitor the efficacy of treatment and ensure that the correct pressure level of the CPAP treatment is being used. However, further development and testing would be required before the device can meet all of the minimum performance requirements. These developments include improving the pressure control and adding the ability for the device to connect to the internet.
dc.identifier.apacitationPhilpott, J. (2024). <i>Design and development of a device to diagnose and treat obstructive sleep apnoea</i>. (). Univerity of Cape Town ,Faculty of Health Sciences ,Department of Human Biology. Retrieved from http://hdl.handle.net/11427/41219en_ZA
dc.identifier.chicagocitationPhilpott, Joel. <i>"Design and development of a device to diagnose and treat obstructive sleep apnoea."</i> ., Univerity of Cape Town ,Faculty of Health Sciences ,Department of Human Biology, 2024. http://hdl.handle.net/11427/41219en_ZA
dc.identifier.citationPhilpott, J. 2024. Design and development of a device to diagnose and treat obstructive sleep apnoea. . Univerity of Cape Town ,Faculty of Health Sciences ,Department of Human Biology. http://hdl.handle.net/11427/41219en_ZA
dc.identifier.ris TY - Thesis / Dissertation AU - Philpott, Joel AB - Sleep apnoea is the repeated cessation of breathing during sleep and can result in impaired concentration, excessive unexplained sleepiness, and sleep fragmentation. Long-term effects of the condition can include hypertension, stroke and cardiovascular disease, diabetes and glucose intolerance, and obesity. Sleep apnoea is linked to a hazard ratio of 1.97, indicating that individuals with this condition face almost twice the risk of experiencing a stroke or death compared to those without sleep apnoea. It is estimated that 425 million adults between the ages of 30 and 69 have moderate to severe sleep apnoea. A study conducted in Wisconsin, America, found that 82% of men and 93% of women with moderate to severe sleep apnoea had not been diagnosed. This is likely to be even higher in low-middle-income countries like South Africa, where there is limited access to healthcare. Limited access to healthcare also affects sleep apnoea treatment. A study conducted in Latin America found that of the 880 patients diagnosed with sleep apnoea, only 55.7% started Positive Airway Pressure (PAP) therapy, as many of the study participants could not afford a basic level of treatment. This study describes the development of a device that could reduce the prevalence of undiagnosed sleep apnoea cases and improve access to treatment. The developed system makes use of standard breathing effort and pulse oximetry sensors as well as a flow sensor to provide the necessary information to conduct a home sleep test for the diagnosis of sleep apnoea, as required by the American Academy of Sleep Medicine (AASM). The diagnostic algorithm proposed by the AASM is also used to identify apnoea events and present this information to a clinician. The system also provides a basic level of Continuous Positive Airway Pressure (CPAP) treatment, the most common treatment modality used for patients with sleep apnoea. The system performance specifications are tested according to the EN ISO 80601-2-70 testing protocol for the mean static pressure, dynamic pressure accuracy, and maximum flow rate. The ISO standard does not dictate minimum performance requirements; however, the device meets most of the requirements dictated by the Association for Respiratory Technology and Physiology (ARTP), except the requirements for the dynamic pressure accuracy where the device exceeded the maximum pressure range by 1.69cmH2O. The study has demonstrated that a single device could be used to address the high prevalence of undiagnosed and untreated sleep apnoea and thereby prevent associated health risks. Using a single device for the diagnosis and treatment of the condition may also allow clinicians to monitor the efficacy of treatment and ensure that the correct pressure level of the CPAP treatment is being used. However, further development and testing would be required before the device can meet all of the minimum performance requirements. These developments include improving the pressure control and adding the ability for the device to connect to the internet. DA - 2024 DB - OpenUCT DP - University of Cape Town KW - human biology LK - https://open.uct.ac.za PB - Univerity of Cape Town PY - 2024 T1 - Design and development of a device to diagnose and treat obstructive sleep apnoea TI - Design and development of a device to diagnose and treat obstructive sleep apnoea UR - http://hdl.handle.net/11427/41219 ER - en_ZA
dc.identifier.urihttp://hdl.handle.net/11427/41219
dc.identifier.vancouvercitationPhilpott J. Design and development of a device to diagnose and treat obstructive sleep apnoea. []. Univerity of Cape Town ,Faculty of Health Sciences ,Department of Human Biology, 2024 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/41219en_ZA
dc.language.isoen
dc.language.rfc3066eng
dc.publisher.departmentDepartment of Human Biology
dc.publisher.facultyFaculty of Health Sciences
dc.publisher.institutionUniverity of Cape Town
dc.subjecthuman biology
dc.titleDesign and development of a device to diagnose and treat obstructive sleep apnoea
dc.typeThesis / Dissertation
dc.type.qualificationlevelMasters
dc.type.qualificationlevelLLM
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
thesis_hsf_2024_philpott joel.pdf
Size:
90.37 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.72 KB
Format:
Item-specific license agreed upon to submission
Description:
Collections