Biomass is a renewable, cost-efficient, carbon-neutral fuel obtained from agricultural waste streams or energy crops that can be combusted in a furnace to co-generate electricity and heat. Integrating a supplementary high efficiency cycle, such as the supercritical-CO2 (sCO2) Brayton cycle, with an existing industrial Rankine cycle and a biomass fired boiler may be an economical option to increase overall thermal efficiency and net generation. However, the integration of sCO2 heaters within the biomass boiler presents challenges related to operating philosophies and component specifications. The focus of this research was to investigate the integration of a sCO2 Brayton cycle with a combined heat and power steam cycle with a modular biomass boiler firing typical Southern African bagasse fuel. A quasi-steady state 1D thermofluid network-based process model of the sCO2, steam and flue gas cycles was developed for nominal and partial load analysis. It accounts for the detailed component characteristics for the Rankine and Brayton cycles, as well as the biomass boiler, together with the complex interactions between all of the components in the different cycles. To facilitate the analysis of these intricate systems, a sophisticated simulation code was developed to allow for necessary customization and enforcement of required boundary conditions and control parameters. The network model solves the mass, energy, momentum, and species balance equations for the various fluid streams, accounting for radiative and convective heat transfer phenomena in the boiler. Due to the novelty of the proposed integrated cycle, high-fidelity 3D CFD modelling was then also used to validate the heat uptakes for the sCO2 heaters in the biomass boiler. Two configurations with the sCO2 heater/s situated within the flue gas flow path were investigated, namely a single convective-dominant heater, and a dual heater configuration with a radiative and a convective heater. At nominal load, the network model results show the required rate of overfiring for the sCO2 configurations, with a 15.3% increase in fuel flow rate resulting in an additional 21.2% in net power output. The impact of the sCO2 heaters situated in the gas flow path was quantified, with reduced heat uptakes for downstream steam heat exchangers offset by increased furnace waterwall heat transfer. At partial loads, between 100%-60%, inventory control proves to be the better performing control strategy for load following, maintaining high thermal efficiency across partial loads. Notably, at 60% load, the sCO2 compressor inlet conditions are near the pseudo-critical point, which requires careful management of inventory control. The boiler CFD modelling highlighted lower heat uptakes for sCO2 heaters compared to the 1D model, exacerbated at lower loads, particularly for the dual heater configuration. The 1D model was consequently calibrated based on these results. The single sCO2 heater configuration is recommended as the preferred configuration to minimise adverse impacts on the Rankine cycle superheaters. Further iterations between the 1D process model and CFD model are recommended.
Description
Reference:
Haffejee, R.A. 2025. A biomass-fueled combined steam and sCO2 heat and power cycle for Southern African conditions. . University of Cape Town ,Faculty of Engineering and the Built Environment ,Department of Mechanical Engineering. http://hdl.handle.net/11427/41603