Parametric study of stresses in cooling-tower shells

dc.contributor.advisorZingoni, Alphose
dc.contributor.authorAjayi, Olugbenga Olumide
dc.date.accessioned2023-09-05T11:02:45Z
dc.date.available2023-09-05T11:02:45Z
dc.date.issued2002
dc.date.updated2023-09-05T10:57:52Z
dc.description.abstractMany attempts have been made in studying the structural behaviour of cooling tower shells, focusing more on the effect of wind on the structure and shape imperfections. However, little has been investigated on the most basic loading condition, i.e. self-weight load. This thesis focuses on a cooling tower with uniform thickness where several geometric parameters like the hyperbolic axis ratio (bla), top opening angle , offset parameters (A), and scale of the structure are varied one at a time, to investigate the effect these parameters have on the meridional and hoop stresses. A general-pwpose finite element programme, ABAQUS, was used to create models of the cooling tower structure. The model results were verified using closed-form analytical membrane solutions as reported by Zingoni. The model considers constraining the base against rotation in all directions while the top is made to be free. The predicted numeric meridional and hoop stresses compare favourably well with the closed-form analytical results, except at the critically stressed zone near the base that exhibits some bending disturbances. Parametric investigation shows that an increase in the hyperbolic axis ratio, the top opening angle, and offset paramete also increases meridional and hoop stresses. It is concluded that lower blao, and zero offset parameters be adopted for preliminary design purposes. Finally, recommendations are made on the need for further investigations.
dc.identifier.apacitationAjayi, O. O. (2002). <i>Parametric study of stresses in cooling-tower shells</i>. (). ,Faculty of Engineering and the Built Environment ,Department of Civil Engineering. Retrieved from http://hdl.handle.net/11427/38378en_ZA
dc.identifier.chicagocitationAjayi, Olugbenga Olumide. <i>"Parametric study of stresses in cooling-tower shells."</i> ., ,Faculty of Engineering and the Built Environment ,Department of Civil Engineering, 2002. http://hdl.handle.net/11427/38378en_ZA
dc.identifier.citationAjayi, O.O. 2002. Parametric study of stresses in cooling-tower shells. . ,Faculty of Engineering and the Built Environment ,Department of Civil Engineering. http://hdl.handle.net/11427/38378en_ZA
dc.identifier.ris TY - Master Thesis AU - Ajayi, Olugbenga Olumide AB - Many attempts have been made in studying the structural behaviour of cooling tower shells, focusing more on the effect of wind on the structure and shape imperfections. However, little has been investigated on the most basic loading condition, i.e. self-weight load. This thesis focuses on a cooling tower with uniform thickness where several geometric parameters like the hyperbolic axis ratio (bla), top opening angle , offset parameters (A), and scale of the structure are varied one at a time, to investigate the effect these parameters have on the meridional and hoop stresses. A general-pwpose finite element programme, ABAQUS, was used to create models of the cooling tower structure. The model results were verified using closed-form analytical membrane solutions as reported by Zingoni. The model considers constraining the base against rotation in all directions while the top is made to be free. The predicted numeric meridional and hoop stresses compare favourably well with the closed-form analytical results, except at the critically stressed zone near the base that exhibits some bending disturbances. Parametric investigation shows that an increase in the hyperbolic axis ratio, the top opening angle, and offset paramete also increases meridional and hoop stresses. It is concluded that lower blao, and zero offset parameters be adopted for preliminary design purposes. Finally, recommendations are made on the need for further investigations. DA - 2002_ DB - OpenUCT DP - University of Cape Town KW - Engineering LK - https://open.uct.ac.za PY - 2002 T1 - Parametric study of stresses in cooling-tower shells TI - Parametric study of stresses in cooling-tower shells UR - http://hdl.handle.net/11427/38378 ER - en_ZA
dc.identifier.urihttp://hdl.handle.net/11427/38378
dc.identifier.vancouvercitationAjayi OO. Parametric study of stresses in cooling-tower shells. []. ,Faculty of Engineering and the Built Environment ,Department of Civil Engineering, 2002 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/38378en_ZA
dc.language.rfc3066eng
dc.publisher.departmentDepartment of Civil Engineering
dc.publisher.facultyFaculty of Engineering and the Built Environment
dc.subjectEngineering
dc.titleParametric study of stresses in cooling-tower shells
dc.typeMaster Thesis
dc.type.qualificationlevelMasters
dc.type.qualificationlevelMSc
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
thesis_ebe_2002_ajayi olugbenga olumide.pdf
Size:
7.33 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
0 B
Format:
Item-specific license agreed upon to submission
Description:
Collections