Distortion Correction in LODOX StatScan X-Ray Images

dc.contributor.authorBeets, Matthew Paul
dc.date.accessioned2024-02-23T06:43:30Z
dc.date.available2024-02-23T06:43:30Z
dc.date.issued2007
dc.date.updated2024-02-23T06:43:04Z
dc.description.abstractThis thesis presents a background and description of a method of distortion correction in x-ray images produced by the LODOX StatScan machine. The distortion correction of an object's x-ray image is of particular interest in the medical field, particularly for prosthetics, implants, and orthopedic work. It is useful to be able to take accurate measurements directly from x-ray images and that these images should be obtained with a minimum of patient discomfort and exposure to radiation. Current x-ray images contain a non-linear distortion that must be corrected for by hand. This distortion is a result of the imaging process: X-rays from a point source spread out before being captured by a detection device such as a photographic plate or an electronic CCD sensor. Because of this, objects closer to the center of the detector suffer less distortion than those at the edges and makes the correction process a non-trivial task traditionally requiring multiple scans to be taken and stitched together manually to minimize the distortion. The method of distortion correction presented here is a novel approach to the problem using the LODOX StatScan machine. It uses multiple scans from the StatScan Machine to create a single completely distortion free image entirely automatically. This is a software based correction method. It takes multiple fan beam x-ray projections and uses them to create a single virtual parallel beam x-ray image suitable for making accurate measurements with.
dc.identifier.apacitationBeets, M. P. (2007). <i>Distortion Correction in LODOX StatScan X-Ray Images</i>. (). ,Faculty of Science ,Department of Computer Science. Retrieved from http://hdl.handle.net/11427/39173en_ZA
dc.identifier.chicagocitationBeets, Matthew Paul. <i>"Distortion Correction in LODOX StatScan X-Ray Images."</i> ., ,Faculty of Science ,Department of Computer Science, 2007. http://hdl.handle.net/11427/39173en_ZA
dc.identifier.citationBeets, M.P. 2007. Distortion Correction in LODOX StatScan X-Ray Images. . ,Faculty of Science ,Department of Computer Science. http://hdl.handle.net/11427/39173en_ZA
dc.identifier.ris TY - Thesis / Dissertation AU - Beets, Matthew Paul AB - This thesis presents a background and description of a method of distortion correction in x-ray images produced by the LODOX StatScan machine. The distortion correction of an object's x-ray image is of particular interest in the medical field, particularly for prosthetics, implants, and orthopedic work. It is useful to be able to take accurate measurements directly from x-ray images and that these images should be obtained with a minimum of patient discomfort and exposure to radiation. Current x-ray images contain a non-linear distortion that must be corrected for by hand. This distortion is a result of the imaging process: X-rays from a point source spread out before being captured by a detection device such as a photographic plate or an electronic CCD sensor. Because of this, objects closer to the center of the detector suffer less distortion than those at the edges and makes the correction process a non-trivial task traditionally requiring multiple scans to be taken and stitched together manually to minimize the distortion. The method of distortion correction presented here is a novel approach to the problem using the LODOX StatScan machine. It uses multiple scans from the StatScan Machine to create a single completely distortion free image entirely automatically. This is a software based correction method. It takes multiple fan beam x-ray projections and uses them to create a single virtual parallel beam x-ray image suitable for making accurate measurements with. DA - 2007 DB - OpenUCT DP - University of Cape Town KW - Computer Science LK - https://open.uct.ac.za PY - 2007 T1 - Distortion Correction in LODOX StatScan X-Ray Images TI - Distortion Correction in LODOX StatScan X-Ray Images UR - http://hdl.handle.net/11427/39173 ER - en_ZA
dc.identifier.urihttp://hdl.handle.net/11427/39173
dc.identifier.vancouvercitationBeets MP. Distortion Correction in LODOX StatScan X-Ray Images. []. ,Faculty of Science ,Department of Computer Science, 2007 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/39173en_ZA
dc.language.rfc3066eng
dc.publisher.departmentDepartment of Computer Science
dc.publisher.facultyFaculty of Science
dc.subjectComputer Science
dc.titleDistortion Correction in LODOX StatScan X-Ray Images
dc.typeThesis / Dissertation
dc.type.qualificationlevelMasters
dc.type.qualificationlevelMasters
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
thesis_sci_2007_beets matthew paul.pdf
Size:
3.79 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.72 KB
Format:
Item-specific license agreed upon to submission
Description:
Collections