A vector based approach for high frequency prospective correction of rigid body motion in Magnetic Resonance Imaging (MRI)

dc.contributor.advisorMeintjes, Ernesta
dc.contributor.advisorvan der Kouwe, Andre
dc.contributor.authorVan Niekerk, Adam Marthinus Johannes
dc.date.accessioned2019-05-15T07:49:33Z
dc.date.available2019-05-15T07:49:33Z
dc.date.issued2019
dc.date.updated2019-05-14T07:12:42Z
dc.description.abstractMagnetic Resonance Imaging (MRI) is remarkable in that it is possible to obtain image resolutions much smaller than the wavelength of the radiated signal. This is achieved through the use of specialised gradient coils that linearly manipulate the magnitude of the magnetic field within the imaging volume. The instantaneous signal received from the subject represents a periodically varying map based on the duration and magnitude (moment) of the previously applied gradient fields. Representing an object as the sum of periodic maps is difficult and as a result many unique gradient moments are required to form an image. When the subject moves the periodic maps are no longer coherent and the constructive/destructive interference becomes invalid. The artefacts are dependent on how and when motion occurred, and manifest as ghosting, ringing and blurring of the image. This thesis describes a novel approach to measuring and correcting for motion as the data are acquired. A small device was constructed that combines observations from a magnetometer (static magnetic field [z]) and an accelerometer (earth’s gravitational field [y]) with an angular rate sensor to determine its orientation with respect to the imaging coordinate frame (VectOrient). It was precise enough to track the subject’s heart beat and breathing and accurate to within one degree. A gradient field probe was then designed for position encoding. The probe measured the rate of change of the gradient magnetic fields using three mutually orthogonal pickup coils. Assuming linear gradients and using Maxwell’s equations, with negligible rates of change of curl and divergence, it was possible to accurately model the three dimensional vector fields that the gradients produce, eliminating the need for a laborious manual calibration. Sub-microsecond synchronisation was achieved by detecting radio frequency pulses in the imaging sequence with a small resonant circuit. This combined with a 2.4 GHz radio link enabled the probe to be wireless. Finally, the pickup coil observations were combined with the vector based orientation estimates and the gradient field model to achieve efficient multidimensional position, orientation and inter-gradient-delay encoding with a 880 µs pulse sequence insert. The Wireless Radio frequency triggered Acquisition Device (WRAD) tracks involuntary and deliberate subject motion, improving image quality without scanner specific calibration.
dc.identifier.apacitationVan Niekerk, A. M. J. (2019). <i>A vector based approach for high frequency prospective correction of rigid body motion in Magnetic Resonance Imaging (MRI)</i>. (). ,Faculty of Health Sciences ,Department of Human Biology. Retrieved from http://hdl.handle.net/11427/30093en_ZA
dc.identifier.chicagocitationVan Niekerk, Adam Marthinus Johannes. <i>"A vector based approach for high frequency prospective correction of rigid body motion in Magnetic Resonance Imaging (MRI)."</i> ., ,Faculty of Health Sciences ,Department of Human Biology, 2019. http://hdl.handle.net/11427/30093en_ZA
dc.identifier.citationVan Niekerk, A.M.J. 2019. A vector based approach for high frequency prospective correction of rigid body motion in Magnetic Resonance Imaging (MRI). . ,Faculty of Health Sciences ,Department of Human Biology. http://hdl.handle.net/11427/30093en_ZA
dc.identifier.ris TY - Thesis / Dissertation AU - Van Niekerk, Adam Marthinus Johannes AB - Magnetic Resonance Imaging (MRI) is remarkable in that it is possible to obtain image resolutions much smaller than the wavelength of the radiated signal. This is achieved through the use of specialised gradient coils that linearly manipulate the magnitude of the magnetic field within the imaging volume. The instantaneous signal received from the subject represents a periodically varying map based on the duration and magnitude (moment) of the previously applied gradient fields. Representing an object as the sum of periodic maps is difficult and as a result many unique gradient moments are required to form an image. When the subject moves the periodic maps are no longer coherent and the constructive/destructive interference becomes invalid. The artefacts are dependent on how and when motion occurred, and manifest as ghosting, ringing and blurring of the image. This thesis describes a novel approach to measuring and correcting for motion as the data are acquired. A small device was constructed that combines observations from a magnetometer (static magnetic field [z]) and an accelerometer (earth’s gravitational field [y]) with an angular rate sensor to determine its orientation with respect to the imaging coordinate frame (VectOrient). It was precise enough to track the subject’s heart beat and breathing and accurate to within one degree. A gradient field probe was then designed for position encoding. The probe measured the rate of change of the gradient magnetic fields using three mutually orthogonal pickup coils. Assuming linear gradients and using Maxwell’s equations, with negligible rates of change of curl and divergence, it was possible to accurately model the three dimensional vector fields that the gradients produce, eliminating the need for a laborious manual calibration. Sub-microsecond synchronisation was achieved by detecting radio frequency pulses in the imaging sequence with a small resonant circuit. This combined with a 2.4 GHz radio link enabled the probe to be wireless. Finally, the pickup coil observations were combined with the vector based orientation estimates and the gradient field model to achieve efficient multidimensional position, orientation and inter-gradient-delay encoding with a 880 µs pulse sequence insert. The Wireless Radio frequency triggered Acquisition Device (WRAD) tracks involuntary and deliberate subject motion, improving image quality without scanner specific calibration. DA - 2019 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PY - 2019 T1 - A vector based approach for high frequency prospective correction of rigid body motion in Magnetic Resonance Imaging (MRI) TI - A vector based approach for high frequency prospective correction of rigid body motion in Magnetic Resonance Imaging (MRI) UR - http://hdl.handle.net/11427/30093 ER - en_ZA
dc.identifier.urihttp://hdl.handle.net/11427/30093
dc.identifier.vancouvercitationVan Niekerk AMJ. A vector based approach for high frequency prospective correction of rigid body motion in Magnetic Resonance Imaging (MRI). []. ,Faculty of Health Sciences ,Department of Human Biology, 2019 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/30093en_ZA
dc.language.rfc3066eng
dc.publisher.departmentDepartment of Human Biology
dc.publisher.facultyFaculty of Health Sciences
dc.titleA vector based approach for high frequency prospective correction of rigid body motion in Magnetic Resonance Imaging (MRI)
dc.typeDoctoral Thesis
dc.type.qualificationlevelDoctoral
dc.type.qualificationnamePhD
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
thesis_hsf_2018_van_niekerk_adam_marthinus_johannes.pdf
Size:
25.81 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
0 B
Format:
Item-specific license agreed upon to submission
Description:
Collections