A methodology for integrated thermofluid modelling of radiant superheaters in steady state and transient operations

dc.contributor.advisorRousseau, Pieter G.
dc.contributor.advisorMalan, Arnaud G.
dc.contributor.advisorJestin, Louis M.
dc.contributor.authorGwebu, Excellent Zibhekele
dc.date.accessioned2019-08-01T07:36:28Z
dc.date.available2019-08-01T07:36:28Z
dc.date.issued2019
dc.date.updated2019-07-31T11:06:23Z
dc.description.abstractCritical components in coal-fired power plants such as final superheater heat exchangers experience severe conditions associated with high metal temperatures and high temperature gradients during base load and transient operations. Such adverse conditions could significantly reduce the life span of the components, especially due to the requirement of greater plant flexibility that is an essential part of the global power system transformation. Integrated thermofluid process models can be employed to obtain a better understanding of the relationship between the operational conditions and the metal temperatures. Thus, a methodology was developed to model radiant superheater heat exchangers in steady state and transient operations. The methodology is based on a network approach which entails solving the transient one-dimensional forms of the conservation equations for mass, energy and momentum. The model building blocks account for the convective thermal resistance on the steam side, the conductive thermal resistances of the tube wall and scaling or fouling on the tube walls, as well as the convective and radiative thermal resistances and direct radiation on the flue gas side. The model captures the physical layout of the tube passes in a tubesheet via the arrangement of the network building blocks. It is also possible to connect tubesheets together across the width of the boiler as per the arrangement in a real plant. The modelling methodology was first used to develop a process model of a convective cross-flow primary superheater heat exchanger with complex flow arrangement. The dual-tube 12-pass superheater was discretized along the flue gas flow path as well as along the steam flow path. The model was qualitatively validated using real plant data from literature and for reference purposes also systematically compared to conventional lumped parameter models. The ability of the model to analyse the effect of ramp rate during load changes on the tube metal temperature was demonstrated, as well as the ability to determine the maldistribution of flow and temperature on the steam and flue gas sides. The methodology was also applied to model a U-shaped radiant superheater heat exchanger. Due to the challenges associated with obtaining comprehensive real plant data in an industrial setting, a validation methodology was proposed that is based on a combination of plant design C-schedules and a boiler mass and energy balance, as well as limited plant measurements. The consistent comparisons with C-schedule data provide evidence of the validity of the model, which was further demonstrated via the comparisons with real plant data. The model allows prediction of the steam mass flow and temperature distribution going into the outlet stub headers as well as the main outlet headers for different inlet flow and temperature distributions on the steam and flue gas sides. These results were compared to detail real-plant measurements of the outlet header temperatures. The model also allows prediction of the metal temperatures along the length of the tubes which cannot readily be measured in the plant. The model was applied to demonstrate the impact of different operational conditions on the tube metal temperatures. Such integrated process models can be employed to study complex thermofluid process phenomena that may occur during intermittent, transient and low load operation of power plants. In addition, such models could be useful for predictive and preventative maintenance as well as online condition monitoring.
dc.identifier.apacitationGwebu, E. Z. (2019). <i>A methodology for integrated thermofluid modelling of radiant superheaters in steady state and transient operations</i>. (). ,Engineering and the Built Environment ,Department of Mechanical Engineering. Retrieved from http://hdl.handle.net/11427/30367en_ZA
dc.identifier.chicagocitationGwebu, Excellent Zibhekele. <i>"A methodology for integrated thermofluid modelling of radiant superheaters in steady state and transient operations."</i> ., ,Engineering and the Built Environment ,Department of Mechanical Engineering, 2019. http://hdl.handle.net/11427/30367en_ZA
dc.identifier.citationGwebu, E.Z. 2019. A methodology for integrated thermofluid modelling of radiant superheaters in steady state and transient operations. . ,Engineering and the Built Environment ,Department of Mechanical Engineering. http://hdl.handle.net/11427/30367en_ZA
dc.identifier.ris TY - Thesis / Dissertation AU - Gwebu, Excellent Zibhekele AB - Critical components in coal-fired power plants such as final superheater heat exchangers experience severe conditions associated with high metal temperatures and high temperature gradients during base load and transient operations. Such adverse conditions could significantly reduce the life span of the components, especially due to the requirement of greater plant flexibility that is an essential part of the global power system transformation. Integrated thermofluid process models can be employed to obtain a better understanding of the relationship between the operational conditions and the metal temperatures. Thus, a methodology was developed to model radiant superheater heat exchangers in steady state and transient operations. The methodology is based on a network approach which entails solving the transient one-dimensional forms of the conservation equations for mass, energy and momentum. The model building blocks account for the convective thermal resistance on the steam side, the conductive thermal resistances of the tube wall and scaling or fouling on the tube walls, as well as the convective and radiative thermal resistances and direct radiation on the flue gas side. The model captures the physical layout of the tube passes in a tubesheet via the arrangement of the network building blocks. It is also possible to connect tubesheets together across the width of the boiler as per the arrangement in a real plant. The modelling methodology was first used to develop a process model of a convective cross-flow primary superheater heat exchanger with complex flow arrangement. The dual-tube 12-pass superheater was discretized along the flue gas flow path as well as along the steam flow path. The model was qualitatively validated using real plant data from literature and for reference purposes also systematically compared to conventional lumped parameter models. The ability of the model to analyse the effect of ramp rate during load changes on the tube metal temperature was demonstrated, as well as the ability to determine the maldistribution of flow and temperature on the steam and flue gas sides. The methodology was also applied to model a U-shaped radiant superheater heat exchanger. Due to the challenges associated with obtaining comprehensive real plant data in an industrial setting, a validation methodology was proposed that is based on a combination of plant design C-schedules and a boiler mass and energy balance, as well as limited plant measurements. The consistent comparisons with C-schedule data provide evidence of the validity of the model, which was further demonstrated via the comparisons with real plant data. The model allows prediction of the steam mass flow and temperature distribution going into the outlet stub headers as well as the main outlet headers for different inlet flow and temperature distributions on the steam and flue gas sides. These results were compared to detail real-plant measurements of the outlet header temperatures. The model also allows prediction of the metal temperatures along the length of the tubes which cannot readily be measured in the plant. The model was applied to demonstrate the impact of different operational conditions on the tube metal temperatures. Such integrated process models can be employed to study complex thermofluid process phenomena that may occur during intermittent, transient and low load operation of power plants. In addition, such models could be useful for predictive and preventative maintenance as well as online condition monitoring. DA - 2019 DB - OpenUCT DP - University of Cape Town KW - Superheater KW - Gas Radiation KW - Direct Radiation KW - Steady Sate KW - Transient LK - https://open.uct.ac.za PY - 2019 T1 - A methodology for integrated thermofluid modelling of radiant superheaters in steady state and transient operations TI - A methodology for integrated thermofluid modelling of radiant superheaters in steady state and transient operations UR - http://hdl.handle.net/11427/30367 ER - en_ZA
dc.identifier.urihttp://hdl.handle.net/11427/30367
dc.identifier.vancouvercitationGwebu EZ. A methodology for integrated thermofluid modelling of radiant superheaters in steady state and transient operations. []. ,Engineering and the Built Environment ,Department of Mechanical Engineering, 2019 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/30367en_ZA
dc.language.rfc3066Eng
dc.publisher.departmentDepartment of Mechanical Engineering
dc.publisher.facultyFaculty of Engineering and the Built Environment
dc.subjectSuperheater
dc.subjectGas Radiation
dc.subjectDirect Radiation
dc.subjectSteady Sate
dc.subjectTransient
dc.titleA methodology for integrated thermofluid modelling of radiant superheaters in steady state and transient operations
dc.typeDoctoral Thesis
dc.type.qualificationlevelDoctoral
dc.type.qualificationnamePhD
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
thesis_ebe_2019_gwebu_excellent_zibhekele.pdf
Size:
17.56 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
0 B
Format:
Item-specific license agreed upon to submission
Description:
Collections