Measurement of neutron radiotherapy spectra in a tissue-equivalent phantom
| dc.contributor.advisor | Brooks, F D | en_ZA |
| dc.contributor.author | Herbert, Mark | en_ZA |
| dc.date.accessioned | 2016-07-04T08:45:22Z | |
| dc.date.available | 2016-07-04T08:45:22Z | |
| dc.date.issued | 1998 | en_ZA |
| dc.description | Bibliography: pages 90-93. | en_ZA |
| dc.description.abstract | A new technique was investigated for determining the changes in neutron radiotherapy spectra with position within a tissue-equivalent phantom at the National Accelerator Centre in the energy range 0 to 63 MeV. An deuterated liquid scintillator (NE230) was used as the neutron spectrometer for these measurements. The pulse height spectra measured using the NE230 scintillator were unfolded to give the neutron spectra. The results show beam hardening with depth into the phantom, which are consistent with other reported findings. The unfolding procedures used are described and the results of the tests performed to verify reliability are also presented and discussed. | en_ZA |
| dc.identifier.apacitation | Herbert, M. (1998). <i>Measurement of neutron radiotherapy spectra in a tissue-equivalent phantom</i>. (Thesis). University of Cape Town ,Faculty of Science ,Department of Physics. Retrieved from http://hdl.handle.net/11427/20201 | en_ZA |
| dc.identifier.chicagocitation | Herbert, Mark. <i>"Measurement of neutron radiotherapy spectra in a tissue-equivalent phantom."</i> Thesis., University of Cape Town ,Faculty of Science ,Department of Physics, 1998. http://hdl.handle.net/11427/20201 | en_ZA |
| dc.identifier.citation | Herbert, M. 1998. Measurement of neutron radiotherapy spectra in a tissue-equivalent phantom. University of Cape Town. | en_ZA |
| dc.identifier.ris | TY - Thesis / Dissertation AU - Herbert, Mark AB - A new technique was investigated for determining the changes in neutron radiotherapy spectra with position within a tissue-equivalent phantom at the National Accelerator Centre in the energy range 0 to 63 MeV. An deuterated liquid scintillator (NE230) was used as the neutron spectrometer for these measurements. The pulse height spectra measured using the NE230 scintillator were unfolded to give the neutron spectra. The results show beam hardening with depth into the phantom, which are consistent with other reported findings. The unfolding procedures used are described and the results of the tests performed to verify reliability are also presented and discussed. DA - 1998 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 1998 T1 - Measurement of neutron radiotherapy spectra in a tissue-equivalent phantom TI - Measurement of neutron radiotherapy spectra in a tissue-equivalent phantom UR - http://hdl.handle.net/11427/20201 ER - | en_ZA |
| dc.identifier.uri | http://hdl.handle.net/11427/20201 | |
| dc.identifier.vancouvercitation | Herbert M. Measurement of neutron radiotherapy spectra in a tissue-equivalent phantom. [Thesis]. University of Cape Town ,Faculty of Science ,Department of Physics, 1998 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/20201 | en_ZA |
| dc.language.iso | eng | en_ZA |
| dc.publisher.department | Department of Physics | en_ZA |
| dc.publisher.faculty | Faculty of Science | en_ZA |
| dc.publisher.institution | University of Cape Town | |
| dc.subject.other | Physics | en_ZA |
| dc.title | Measurement of neutron radiotherapy spectra in a tissue-equivalent phantom | en_ZA |
| dc.type | Master Thesis | |
| dc.type.qualificationlevel | Masters | |
| dc.type.qualificationname | MSc | en_ZA |
| uct.type.filetype | Text | |
| uct.type.filetype | Image | |
| uct.type.publication | Research | en_ZA |
| uct.type.resource | Thesis | en_ZA |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- thesis_sci_1998_herbert_mark.pdf
- Size:
- 19.23 MB
- Format:
- Adobe Portable Document Format
- Description: