Volumetric modulated Arc Therapy versus 3D conformal radiotherapy in the treatment of locally advanced cervical cancer. A single institution, comparative dosimetric study

dc.contributor.advisorFakie, Nazia
dc.contributor.authorBhagaloo, Visham
dc.date.accessioned2021-01-20T13:31:49Z
dc.date.available2021-01-20T13:31:49Z
dc.date.issued2020
dc.date.updated2021-01-04T11:47:03Z
dc.description.abstractBackground: External Beam Radiotherapy is essential in the management of locally advanced cervical cancer (LACC). Generally, VMAT is thought to achieve higher conformity to the Planned Target Volume (PTV) and better sparing of organs at risk (OAR) when compared to 3D-CRT. This study focused on these principles as it applied to treatment and potential toxicity in the management of LACC. Aim: To compare dosimetric parameters between VMAT and 3D-CRT in the management of LACC. Setting: The study analysed patients treated at Groote Schuur Hospital between May and December 2017. Method: A non-randomized comparative retrospective study. EBRT plans for 3D-CRT and VMAT were generated and data on treatment parameters for PTV D50%, Dmax, Dmean, Conformity Index (CI), Homogeneity Index, Treated Volume (TV), Irradiated Volume (IV) and OAR constraints; femoral heads, bladder, bowel bag, rectum and bone marrow were collected. Results: Of the 45 patients assessed, VMAT showed significantly lower treatment parameter values for CI (1.09 vs 1.49; p< .001) whereas, 3D-CRT showed lower Dmax (48.1Gy vs 49.2Gy; p< .001) and rectum (88.5% vs 96%). A reduced 3D-CRT dose was noted for bladder Dmax (47.4Gy vs 48.3Gy; p< .001). Conclusion: VMAT offered a superior dosimetric option, with better OAR dose sparing and optimal tumour dosimetry.
dc.identifier.apacitationBhagaloo, V. (2020). <i>Volumetric modulated Arc Therapy versus 3D conformal radiotherapy in the treatment of locally advanced cervical cancer. A single institution, comparative dosimetric study</i>. (). ,Faculty of Health Sciences ,Division of Radiology. Retrieved from http://hdl.handle.net/11427/32601en_ZA
dc.identifier.chicagocitationBhagaloo, Visham. <i>"Volumetric modulated Arc Therapy versus 3D conformal radiotherapy in the treatment of locally advanced cervical cancer. A single institution, comparative dosimetric study."</i> ., ,Faculty of Health Sciences ,Division of Radiology, 2020. http://hdl.handle.net/11427/32601en_ZA
dc.identifier.citationBhagaloo, V. 2020. Volumetric modulated Arc Therapy versus 3D conformal radiotherapy in the treatment of locally advanced cervical cancer. A single institution, comparative dosimetric study. . ,Faculty of Health Sciences ,Division of Radiology. http://hdl.handle.net/11427/32601en_ZA
dc.identifier.ris TY - Master Thesis AU - Bhagaloo, Visham AB - Background: External Beam Radiotherapy is essential in the management of locally advanced cervical cancer (LACC). Generally, VMAT is thought to achieve higher conformity to the Planned Target Volume (PTV) and better sparing of organs at risk (OAR) when compared to 3D-CRT. This study focused on these principles as it applied to treatment and potential toxicity in the management of LACC. Aim: To compare dosimetric parameters between VMAT and 3D-CRT in the management of LACC. Setting: The study analysed patients treated at Groote Schuur Hospital between May and December 2017. Method: A non-randomized comparative retrospective study. EBRT plans for 3D-CRT and VMAT were generated and data on treatment parameters for PTV D50%, Dmax, Dmean, Conformity Index (CI), Homogeneity Index, Treated Volume (TV), Irradiated Volume (IV) and OAR constraints; femoral heads, bladder, bowel bag, rectum and bone marrow were collected. Results: Of the 45 patients assessed, VMAT showed significantly lower treatment parameter values for CI (1.09 vs 1.49; p< .001) whereas, 3D-CRT showed lower Dmax (48.1Gy vs 49.2Gy; p< .001) and rectum (88.5% vs 96%). A reduced 3D-CRT dose was noted for bladder Dmax (47.4Gy vs 48.3Gy; p< .001). Conclusion: VMAT offered a superior dosimetric option, with better OAR dose sparing and optimal tumour dosimetry. DA - 2020_ DB - OpenUCT DP - University of Cape Town KW - Cervical cancer KW - VMAT KW - 3D-CRT KW - radiation therapy KW - dosimetry LK - https://open.uct.ac.za PY - 2020 T1 - Volumetric modulated Arc Therapy versus 3D conformal radiotherapy in the treatment of locally advanced cervical cancer. A single institution, comparative dosimetric study TI - Volumetric modulated Arc Therapy versus 3D conformal radiotherapy in the treatment of locally advanced cervical cancer. A single institution, comparative dosimetric study UR - http://hdl.handle.net/11427/32601 ER - en_ZA
dc.identifier.urihttp://hdl.handle.net/11427/32601
dc.identifier.vancouvercitationBhagaloo V. Volumetric modulated Arc Therapy versus 3D conformal radiotherapy in the treatment of locally advanced cervical cancer. A single institution, comparative dosimetric study. []. ,Faculty of Health Sciences ,Division of Radiology, 2020 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/32601en_ZA
dc.language.rfc3066eng
dc.publisher.departmentDivision of Radiology
dc.publisher.facultyFaculty of Health Sciences
dc.subjectCervical cancer
dc.subjectVMAT
dc.subject3D-CRT
dc.subjectradiation therapy
dc.subjectdosimetry
dc.titleVolumetric modulated Arc Therapy versus 3D conformal radiotherapy in the treatment of locally advanced cervical cancer. A single institution, comparative dosimetric study
dc.typeMaster Thesis
dc.type.qualificationlevelMasters
dc.type.qualificationlevelMMed
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
thesis_hsf_2020_bhagaloo visham.pdf
Size:
2.7 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
0 B
Format:
Item-specific license agreed upon to submission
Description:
Collections