Elliptical Subject Specific model for respiratory motion
dc.contributor.author | Burger, Ian | en_ZA |
dc.contributor.author | Meintjes, Ernesta | en_ZA |
dc.contributor.author | Keegan, Jennifer | en_ZA |
dc.contributor.author | Firmin, David | en_ZA |
dc.date.accessioned | 2015-10-30T09:26:16Z | |
dc.date.available | 2015-10-30T09:26:16Z | |
dc.date.issued | 2012 | en_ZA |
dc.description.abstract | Respiratory motion of the heart poses a problem for high resolution cardiac MR imaging. Prospective slice following uses the navigator position immediately prior to the imaging segment to correct the slice positions throughout the segment [1]. The navigator is typically placed over the right hemi-diaphragm and a fixed correction factor is used to adjust for the difference to the motion of the heart. The relationship between the motion of the heart and the superior-inferior motion of the diaphragm is approximately linear although highly subject specific, with an element of hysteresis [2]. We investigated a more complex model to incorporate non rigid transformation of the heart as well as hysteresis. | en_ZA |
dc.identifier.apacitation | Burger, I., Meintjes, E., Keegan, J., & Firmin, D. (2012). Elliptical Subject Specific model for respiratory motion. <i>Journal of Cardiovascular Magnetic Resonance</i>, http://hdl.handle.net/11427/14494 | en_ZA |
dc.identifier.chicagocitation | Burger, Ian, Ernesta Meintjes, Jennifer Keegan, and David Firmin "Elliptical Subject Specific model for respiratory motion." <i>Journal of Cardiovascular Magnetic Resonance</i> (2012) http://hdl.handle.net/11427/14494 | en_ZA |
dc.identifier.citation | Burger, I., Meintjes, E. M., Keegan, J., & Firmin, D. N. (2012). Elliptical Subject Specific model for respiratory motion. Journal of Cardiovascular Magnetic Resonance, 14(1), 1-2. | en_ZA |
dc.identifier.ris | TY - Journal Article AU - Burger, Ian AU - Meintjes, Ernesta AU - Keegan, Jennifer AU - Firmin, David AB - Respiratory motion of the heart poses a problem for high resolution cardiac MR imaging. Prospective slice following uses the navigator position immediately prior to the imaging segment to correct the slice positions throughout the segment [1]. The navigator is typically placed over the right hemi-diaphragm and a fixed correction factor is used to adjust for the difference to the motion of the heart. The relationship between the motion of the heart and the superior-inferior motion of the diaphragm is approximately linear although highly subject specific, with an element of hysteresis [2]. We investigated a more complex model to incorporate non rigid transformation of the heart as well as hysteresis. DA - 2012 DB - OpenUCT DO - 10.1186/1532-429X-14-S1-P267 DP - University of Cape Town J1 - Journal of Cardiovascular Magnetic Resonance LK - https://open.uct.ac.za PB - University of Cape Town PY - 2012 T1 - Elliptical Subject Specific model for respiratory motion TI - Elliptical Subject Specific model for respiratory motion UR - http://hdl.handle.net/11427/14494 ER - | en_ZA |
dc.identifier.uri | http://hdl.handle.net/11427/14494 | |
dc.identifier.uri | http://dx.doi.org/10.1186/1532-429X-14-S1-P267 | |
dc.identifier.vancouvercitation | Burger I, Meintjes E, Keegan J, Firmin D. Elliptical Subject Specific model for respiratory motion. Journal of Cardiovascular Magnetic Resonance. 2012; http://hdl.handle.net/11427/14494. | en_ZA |
dc.language.iso | eng | en_ZA |
dc.publisher | Biomed Central Ltd | en_ZA |
dc.publisher.department | MRC/UCT Medical Imaging Research Unit | en_ZA |
dc.publisher.faculty | Faculty of Health Sciences | en_ZA |
dc.publisher.institution | University of Cape Town | |
dc.rights | This is an Open Access article distributed under the terms of the Creative Commons Attribution License | en_ZA |
dc.rights.holder | 2012 Burger et al; licensee BioMed Central Ltd. | en_ZA |
dc.rights.uri | http://creativecommons.org/licenses/by/2.0 | en_ZA |
dc.source | Journal of Cardiovascular Magnetic Resonance | en_ZA |
dc.source.uri | http://www.jcmr-online.com/ | en_ZA |
dc.subject.other | Cardiovascular Magnetic Resonance | en_ZA |
dc.title | Elliptical Subject Specific model for respiratory motion | en_ZA |
dc.type | Journal Article | en_ZA |
uct.type.filetype | Text | |
uct.type.filetype | Image | |
uct.type.publication | Research | en_ZA |
uct.type.resource | Article | en_ZA |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Burger_Elliptical_Subject_Specific_model_2012.pdf
- Size:
- 480.3 KB
- Format:
- Adobe Portable Document Format
- Description: