The Development of a Patient-Specific, Open Source Computational Fluid Dynamics Tool to Comprehensively and Innovatively Study Coarctation of the Aorta in a Limited Resource Clinical Context

dc.contributor.advisorNgoepe, Malebogo
dc.contributor.advisorZuhlke, Liesl
dc.contributor.authorSwanson, Liam
dc.date.accessioned2021-03-01T18:26:33Z
dc.date.available2021-03-01T18:26:33Z
dc.date.issued2020
dc.date.updated2021-03-01T13:56:32Z
dc.description.abstractCongenital heart disease (CHD) has a global prevalence of 8 per 1000 births [1] and coarctation of the aorta (CoA) is one of the most common defects with a prevalence of 7% of all cases. The occurrence of CHD in Africa is estimated to be significantly lower, which is attributed to a lack of data [2]. This emphasises the restricted human resources, as well as diagnostic and intervention capacity of specialists in Africa which leads to delayed treatment, presentation with established severity and, consequently, a worse prognosis. Computational Fluid Dynamics (CFD) is seen as the tool that will lead to a better understanding of the haemodynamic effects caused by the malformations related to CoA and provide insights into post-repair morbidity. In addition, the development of a computational tool is envisaged to improve the clinical capacity for diagnosis as well as provide a tool to conduct in silico repair planning. In a low and lower-middle income country healthcare facility, the supplementary data that CFD can provide can add diagnostic value, plan interventions to be more effective and efficient, as well as provide data that may improve postrepair patient management. The aim of this project is to develop a patient-specific, open source, computational fluid dynamics toolchain that is able to study the haemodynamics relating to CoA. In order to do so, a protocol for the collection of doppler echocardiography (echo) and CTA data is proposed. The method for processing the echo data and manually segmenting the CTA data is presented and evaluated. The open source, OpenFOAM code is used to simulate a patient-specific CoA case as well as two in silico designs of coarctation repairs based on expanding the coarctation from the original dataset. The CFD toolchain was developed such that patient data collected from the hospital could be processed to present key haemodynamic metrics such as velocities in the field at the coarctation zone, the pressure gradient across the coarctation and volumetric flow rates through each supra-aortic branch. These results are obtained for each case's geometry, and the trends and impacts that increasing the coarctation ratio has on each of the haemodynamic metrics is presented. The results show that the coarctation pressure gradient and maximum coarctation velocity decrease while perfusion of the lower limbs recovers with expanding coarctation ratio. Following an analysis of the results, it is evident that the pipeline is capable of running patient-specific CFD simulations and can present clinically relevant results. It is noted that this work is a proof of concept and so several steps are discussed that will improve the pipeline.
dc.identifier.apacitationSwanson, L. (2020). <i>The Development of a Patient-Specific, Open Source Computational Fluid Dynamics Tool to Comprehensively and Innovatively Study Coarctation of the Aorta in a Limited Resource Clinical Context</i>. (). ,Faculty of Engineering and the Built Environment ,Department of Mechanical Engineering. Retrieved from http://hdl.handle.net/11427/33033en_ZA
dc.identifier.chicagocitationSwanson, Liam. <i>"The Development of a Patient-Specific, Open Source Computational Fluid Dynamics Tool to Comprehensively and Innovatively Study Coarctation of the Aorta in a Limited Resource Clinical Context."</i> ., ,Faculty of Engineering and the Built Environment ,Department of Mechanical Engineering, 2020. http://hdl.handle.net/11427/33033en_ZA
dc.identifier.citationSwanson, L. 2020. The Development of a Patient-Specific, Open Source Computational Fluid Dynamics Tool to Comprehensively and Innovatively Study Coarctation of the Aorta in a Limited Resource Clinical Context. . ,Faculty of Engineering and the Built Environment ,Department of Mechanical Engineering. http://hdl.handle.net/11427/33033en_ZA
dc.identifier.ris TY - Master Thesis AU - Swanson, Liam AB - Congenital heart disease (CHD) has a global prevalence of 8 per 1000 births [1] and coarctation of the aorta (CoA) is one of the most common defects with a prevalence of 7% of all cases. The occurrence of CHD in Africa is estimated to be significantly lower, which is attributed to a lack of data [2]. This emphasises the restricted human resources, as well as diagnostic and intervention capacity of specialists in Africa which leads to delayed treatment, presentation with established severity and, consequently, a worse prognosis. Computational Fluid Dynamics (CFD) is seen as the tool that will lead to a better understanding of the haemodynamic effects caused by the malformations related to CoA and provide insights into post-repair morbidity. In addition, the development of a computational tool is envisaged to improve the clinical capacity for diagnosis as well as provide a tool to conduct in silico repair planning. In a low and lower-middle income country healthcare facility, the supplementary data that CFD can provide can add diagnostic value, plan interventions to be more effective and efficient, as well as provide data that may improve postrepair patient management. The aim of this project is to develop a patient-specific, open source, computational fluid dynamics toolchain that is able to study the haemodynamics relating to CoA. In order to do so, a protocol for the collection of doppler echocardiography (echo) and CTA data is proposed. The method for processing the echo data and manually segmenting the CTA data is presented and evaluated. The open source, OpenFOAM code is used to simulate a patient-specific CoA case as well as two in silico designs of coarctation repairs based on expanding the coarctation from the original dataset. The CFD toolchain was developed such that patient data collected from the hospital could be processed to present key haemodynamic metrics such as velocities in the field at the coarctation zone, the pressure gradient across the coarctation and volumetric flow rates through each supra-aortic branch. These results are obtained for each case's geometry, and the trends and impacts that increasing the coarctation ratio has on each of the haemodynamic metrics is presented. The results show that the coarctation pressure gradient and maximum coarctation velocity decrease while perfusion of the lower limbs recovers with expanding coarctation ratio. Following an analysis of the results, it is evident that the pipeline is capable of running patient-specific CFD simulations and can present clinically relevant results. It is noted that this work is a proof of concept and so several steps are discussed that will improve the pipeline. DA - 2020_ DB - OpenUCT DP - University of Cape Town KW - Mechanical Engineering LK - https://open.uct.ac.za PY - 2020 T1 - The Development of a Patient-Specific, Open Source Computational Fluid Dynamics Tool to Comprehensively and Innovatively Study Coarctation of the Aorta in a Limited Resource Clinical Context TI - The Development of a Patient-Specific, Open Source Computational Fluid Dynamics Tool to Comprehensively and Innovatively Study Coarctation of the Aorta in a Limited Resource Clinical Context UR - http://hdl.handle.net/11427/33033 ER - en_ZA
dc.identifier.urihttp://hdl.handle.net/11427/33033
dc.identifier.vancouvercitationSwanson L. The Development of a Patient-Specific, Open Source Computational Fluid Dynamics Tool to Comprehensively and Innovatively Study Coarctation of the Aorta in a Limited Resource Clinical Context. []. ,Faculty of Engineering and the Built Environment ,Department of Mechanical Engineering, 2020 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/33033en_ZA
dc.language.rfc3066eng
dc.publisher.departmentDepartment of Mechanical Engineering
dc.publisher.facultyFaculty of Engineering and the Built Environment
dc.subjectMechanical Engineering
dc.titleThe Development of a Patient-Specific, Open Source Computational Fluid Dynamics Tool to Comprehensively and Innovatively Study Coarctation of the Aorta in a Limited Resource Clinical Context
dc.typeMaster Thesis
dc.type.qualificationlevelMasters
dc.type.qualificationlevelMSc
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
thesis_ebe_2020_swanson liam.pdf
Size:
7.21 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
0 B
Format:
Item-specific license agreed upon to submission
Description:
Collections