Sub-Millimetre Positron-Emission Particle Tracking Using a CdZnTe Semiconductor Array

dc.contributor.advisorPeterson, Steven
dc.contributor.advisorLeadbeater, Tom
dc.contributor.authorHyslop, Nicholas
dc.date.accessioned2022-02-22T08:28:54Z
dc.date.available2022-02-22T08:28:54Z
dc.date.issued2021
dc.date.updated2022-02-16T08:07:28Z
dc.description.abstractThe Positron Emission Particle Tracking (PEPT) technique has been in development in Cape Town since 2009, and typically allows the tracking of a 1 mm diameter positron-emitting source travelling at 1 m/s with precision around 1 mm at kHz rates. Conventionally, PEPT utilises large, high efficiency scintillator detectors and relies on high data-rates obtained from high activity tracer particles to achieve the quoted performance. However, as we look to apply the technique to more challenging liquid and mixed phase systems, smaller tracer particles are required (of the order 10 µm) which are necessarily limited in attainable activity and therefore applicability in current systems. This dissertation investigated the use of pixelated room-temperature semiconductor CdZnTe detectors with high pixel resolution to implement PEPT. Using a PolarisJ CZT detector module array built by H3D Inc. (Ann Arbor, MI, USA) with a field-of-view of 40 × 60 × 20 mm3 , a positron-emitting 22Na source (1 mm diameter) with an activity of 20 kBq was located in three-dimensional space with a radial location uncertainty of < 600 µm (68% coverage) and location rate of ≈ 0.3 Hz. A 68Ga source (160 µm diameter) with an activity of 1 MBq was located with a radial position uncertainty of < 800 µm (68% coverage) and location rate of ≈ 10 Hz. A 37 kBq 22Na tracer was tracked with sub-millimetre precision undergoing circular motion at radii between 0.5 - 20 mm and speeds between 0.25 and 15 mm/s. We have showed sub-millimetre tracking of tracer particles with tracer activities orders of magnitude lower than currently possible using conventional PEPT systems. A potential application of this work is in providing on-line beam diagnostics in proton radiotherapy. The PEPT technique was therefore applied to Geant4 simulation data of a 55 MeV and 200 MeV proton beam passing through an organic target to locate the beam-line with uncertainties within the incoming beam width. Such proton beams produce positron emitters at activities too low to measure with conventional scintillators. With the current CZT arrays already in use for dose verification imaging, incorporating such beam-tracking to improve image quality can be easily implemented in future.
dc.identifier.apacitationHyslop, N. (2021). <i>Sub-Millimetre Positron-Emission Particle Tracking Using a CdZnTe Semiconductor Array</i>. (). ,Faculty of Science ,Department of Physics. Retrieved from http://hdl.handle.net/11427/35825en_ZA
dc.identifier.chicagocitationHyslop, Nicholas. <i>"Sub-Millimetre Positron-Emission Particle Tracking Using a CdZnTe Semiconductor Array."</i> ., ,Faculty of Science ,Department of Physics, 2021. http://hdl.handle.net/11427/35825en_ZA
dc.identifier.citationHyslop, N. 2021. Sub-Millimetre Positron-Emission Particle Tracking Using a CdZnTe Semiconductor Array. . ,Faculty of Science ,Department of Physics. http://hdl.handle.net/11427/35825en_ZA
dc.identifier.ris TY - Master Thesis AU - Hyslop, Nicholas AB - The Positron Emission Particle Tracking (PEPT) technique has been in development in Cape Town since 2009, and typically allows the tracking of a 1 mm diameter positron-emitting source travelling at 1 m/s with precision around 1 mm at kHz rates. Conventionally, PEPT utilises large, high efficiency scintillator detectors and relies on high data-rates obtained from high activity tracer particles to achieve the quoted performance. However, as we look to apply the technique to more challenging liquid and mixed phase systems, smaller tracer particles are required (of the order 10 µm) which are necessarily limited in attainable activity and therefore applicability in current systems. This dissertation investigated the use of pixelated room-temperature semiconductor CdZnTe detectors with high pixel resolution to implement PEPT. Using a PolarisJ CZT detector module array built by H3D Inc. (Ann Arbor, MI, USA) with a field-of-view of 40 × 60 × 20 mm3 , a positron-emitting 22Na source (1 mm diameter) with an activity of 20 kBq was located in three-dimensional space with a radial location uncertainty of < 600 µm (68% coverage) and location rate of ≈ 0.3 Hz. A 68Ga source (160 µm diameter) with an activity of 1 MBq was located with a radial position uncertainty of < 800 µm (68% coverage) and location rate of ≈ 10 Hz. A 37 kBq 22Na tracer was tracked with sub-millimetre precision undergoing circular motion at radii between 0.5 - 20 mm and speeds between 0.25 and 15 mm/s. We have showed sub-millimetre tracking of tracer particles with tracer activities orders of magnitude lower than currently possible using conventional PEPT systems. A potential application of this work is in providing on-line beam diagnostics in proton radiotherapy. The PEPT technique was therefore applied to Geant4 simulation data of a 55 MeV and 200 MeV proton beam passing through an organic target to locate the beam-line with uncertainties within the incoming beam width. Such proton beams produce positron emitters at activities too low to measure with conventional scintillators. With the current CZT arrays already in use for dose verification imaging, incorporating such beam-tracking to improve image quality can be easily implemented in future. DA - 2021_ DB - OpenUCT DP - University of Cape Town KW - Physics LK - https://open.uct.ac.za PY - 2021 T1 - Sub-Millimetre Positron-Emission Particle Tracking Using a CdZnTe Semiconductor Array TI - Sub-Millimetre Positron-Emission Particle Tracking Using a CdZnTe Semiconductor Array UR - http://hdl.handle.net/11427/35825 ER - en_ZA
dc.identifier.urihttp://hdl.handle.net/11427/35825
dc.identifier.vancouvercitationHyslop N. Sub-Millimetre Positron-Emission Particle Tracking Using a CdZnTe Semiconductor Array. []. ,Faculty of Science ,Department of Physics, 2021 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/35825en_ZA
dc.language.rfc3066eng
dc.publisher.departmentDepartment of Physics
dc.publisher.facultyFaculty of Science
dc.subjectPhysics
dc.titleSub-Millimetre Positron-Emission Particle Tracking Using a CdZnTe Semiconductor Array
dc.typeMaster Thesis
dc.type.qualificationlevelMasters
dc.type.qualificationlevelMSc
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
thesis_sci_2021_hyslop nicholas.pdf
Size:
109.52 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
0 B
Format:
Item-specific license agreed upon to submission
Description:
Collections