Ventilation in minibus taxis as a means of airborne infection control

dc.contributor.advisorPoluta, Mladen
dc.contributor.advisorDouglas, Tania
dc.contributor.authorMatose, Munyaradzi T
dc.date.accessioned2019-02-13T15:46:47Z
dc.date.available2019-02-13T15:46:47Z
dc.date.issued2018
dc.date.updated2019-02-13T12:10:27Z
dc.description.abstractAirborne infection control (AIC) measures are used extensively in healthcare settings to curtail the spread of airborne infectious diseases; these measures include administrative, architectural, engineering (e.g. ventilation) and personal protective interventions, serving either to reduce the concentration of airborne infectious particles or to protect individuals from direct exposure to airborne infection. Few such measures are applied in public congregate spaces outside of health facilities, such as those associated with public transport. Limited literature is available on existing AIC measures in the context of public transport modalities. This study explores the role of ventilation as an AIC measure in minibus taxis in Cape Town, South Africa, to determine its potential role in reducing airborne infectious disease transmission. The minibus taxi model chosen for the study was the Toyota Quantum Ses’fikile, which is commonly used in the Cape Town metropole. The Ses’fikile taxi has 6 windows, 2 at the front, 2 in line with the main passenger door and 2 towards the rear of the taxi. Ultrasonic anemometers were placed at key positions throughout the taxi-interior to measure and log airflow patterns, under different widow-open/close configurations and at different taxi speeds. To determine ventilation rates, the configurations were tested in an occupied taxi, with occupants comprising the driver, a researcher, and 14 volunteer participants. This study analysed TB transmission risk using the Issarow equation, a dose-response model. Airflows created by different window configurations produced patterns in airflow direction and velocity. A linear regression model fit to the ventilation data revealed that increasing taxi speed increased ventilation. Ventilation rates were found to depend on interior airflow as a result of the window configuration, as well as on the number of open windows, although the ventilation rate was not highest with the highest number of open windows. The best ventilation rates were found with four open windows, which included the front windows on both sides of the vehicle, and either the middle windows on both sides or the rear windows on both sides. The ventilation rates produced by these configurations at all tested taxi speeds (40 km/h, 80 km/h and 100 km/h) ranged from 108 to 316 L/s and exceeded the World Health Organization recommendation for new healthcare facilities, airborne precaution rooms, and general wards and outpatient departments. TB transmission probabilities in a taxi were dependent on ventilation, occupancy, number of infectors and duration of exposure. The risk of transmission was shown to increase substantially when ventilation rates fell below 50 L/s. In conclusion, minibus taxis were found to provide an effective range of ventilation rates that reduce the risk of TB transmission at varying speeds, however when natural ventilation is not used and with typical high occupancies, the risk posed to all occupants is high. Alternative AIC interventions may have to be considered.
dc.identifier.apacitationMatose, M. T. (2018). <i>Ventilation in minibus taxis as a means of airborne infection control</i>. (). University of Cape Town ,Faculty of Health Sciences ,Department of Human Biology. Retrieved from http://hdl.handle.net/11427/29511en_ZA
dc.identifier.chicagocitationMatose, Munyaradzi T. <i>"Ventilation in minibus taxis as a means of airborne infection control."</i> ., University of Cape Town ,Faculty of Health Sciences ,Department of Human Biology, 2018. http://hdl.handle.net/11427/29511en_ZA
dc.identifier.citationMatose, M. 2018. Ventilation in minibus taxis as a means of airborne infection control. University of Cape Town.en_ZA
dc.identifier.ris TY - Thesis / Dissertation AU - Matose, Munyaradzi T AB - Airborne infection control (AIC) measures are used extensively in healthcare settings to curtail the spread of airborne infectious diseases; these measures include administrative, architectural, engineering (e.g. ventilation) and personal protective interventions, serving either to reduce the concentration of airborne infectious particles or to protect individuals from direct exposure to airborne infection. Few such measures are applied in public congregate spaces outside of health facilities, such as those associated with public transport. Limited literature is available on existing AIC measures in the context of public transport modalities. This study explores the role of ventilation as an AIC measure in minibus taxis in Cape Town, South Africa, to determine its potential role in reducing airborne infectious disease transmission. The minibus taxi model chosen for the study was the Toyota Quantum Ses’fikile, which is commonly used in the Cape Town metropole. The Ses’fikile taxi has 6 windows, 2 at the front, 2 in line with the main passenger door and 2 towards the rear of the taxi. Ultrasonic anemometers were placed at key positions throughout the taxi-interior to measure and log airflow patterns, under different widow-open/close configurations and at different taxi speeds. To determine ventilation rates, the configurations were tested in an occupied taxi, with occupants comprising the driver, a researcher, and 14 volunteer participants. This study analysed TB transmission risk using the Issarow equation, a dose-response model. Airflows created by different window configurations produced patterns in airflow direction and velocity. A linear regression model fit to the ventilation data revealed that increasing taxi speed increased ventilation. Ventilation rates were found to depend on interior airflow as a result of the window configuration, as well as on the number of open windows, although the ventilation rate was not highest with the highest number of open windows. The best ventilation rates were found with four open windows, which included the front windows on both sides of the vehicle, and either the middle windows on both sides or the rear windows on both sides. The ventilation rates produced by these configurations at all tested taxi speeds (40 km/h, 80 km/h and 100 km/h) ranged from 108 to 316 L/s and exceeded the World Health Organization recommendation for new healthcare facilities, airborne precaution rooms, and general wards and outpatient departments. TB transmission probabilities in a taxi were dependent on ventilation, occupancy, number of infectors and duration of exposure. The risk of transmission was shown to increase substantially when ventilation rates fell below 50 L/s. In conclusion, minibus taxis were found to provide an effective range of ventilation rates that reduce the risk of TB transmission at varying speeds, however when natural ventilation is not used and with typical high occupancies, the risk posed to all occupants is high. Alternative AIC interventions may have to be considered. DA - 2018 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2018 T1 - Ventilation in minibus taxis as a means of airborne infection control TI - Ventilation in minibus taxis as a means of airborne infection control UR - http://hdl.handle.net/11427/29511 ER - en_ZA
dc.identifier.urihttp://hdl.handle.net/11427/29511
dc.identifier.vancouvercitationMatose MT. Ventilation in minibus taxis as a means of airborne infection control. []. University of Cape Town ,Faculty of Health Sciences ,Department of Human Biology, 2018 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/29511en_ZA
dc.language.isoeng
dc.publisher.departmentDepartment of Human Biology
dc.publisher.facultyFaculty of Health Sciences
dc.publisher.institutionUniversity of Cape Town
dc.subject.otherBiomedical Engineering
dc.titleVentilation in minibus taxis as a means of airborne infection control
dc.typeMaster Thesis
dc.type.qualificationlevelMasters
dc.type.qualificationnameMSc (Med)
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
thesis_hsf_2018_matose_munyaradzi_t.pdf
Size:
8.49 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
0 B
Format:
Item-specific license agreed upon to submission
Description:
Collections