Browsing by Subject "Femelle"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
- ItemOpen AccessCombined assessment (aspiration cytology and mammography) of clinically suspicious breast masses(1995) VAN WYK, W; Dent, D; HACKING, E; LEARMONTH, G; KOTTLER, R; GUDGEON, C; Tiltman, AWe examined the safety and utility of the combined assessment of aspiration cytology and mammography in 705 women who had clinically suspicious or malignant palpable breast masses. Histological assessment confirmed 176 benign and 529 malignant lesions. There were no incorrect (false positive) diagnoses made in the 176 benign masses when combined assessment was used (specificity 1,0; predictive value 0,86); in isolation, however, there was a false positive cytological diagnosis («papillary carcinoma») and 3 false positive mammographic diagnoses. Benign disease (false negative) was incorrectly diagnosed by combined assessment in 4 of the 529 malignant masses (sensitivity 0,99; predictive value 0,98): cytological diagnoses were of fat necrosis (2) and benign cells on cytospin (1) and aspiration biopsy (1); mammographic diagnoses were of benign disease (2) and normality (2). Indeterminate («atypical», «suspicious») diagnoses were problematic and frequent (overall 223 (31,6%), malignant masses 137 (25,9%), benign masses 86 (48,9%); cytology 117 (16,6%), mammography 141 (20%). Thus, with the combined assessment of mammography and cytology in clinically suspicious breast masses, a decisive diagnosis was made in about two-thirds of cases allowing the safe commencement of therapy; the balance of patients required cone or excision biopsy.
- ItemOpen AccessComparison of body fatness measurements by near-infrared reactance and dual-energy X-ray absorptiometry in normal-weight and obese black and white women(2010) Jennings, Courtney L; Micklesfield, Lisa K; Lambert, Mike I; Lambert, Estelle V; Collins, Malcolm; Goedecke, Julia HThe aim of the present study was to compare body fat percent (BF %) using single-site near-IR reactance (NIR) and dual-energy X-ray absorptiometry (DXA) in a cohort of normal-weight (BMI < 25 kg/m2) black (n 102) and white (n 71); and obese (BMI > or = 30 kg/m2) black (n 117) and white (n 41) South African women (18-45 years). NIR-derived BF % was significantly correlated with DXA-derived BF % in all groups: normal-weight black (r 0.55, 95 % CI: 0.40, 0.67, P < 0.001) and white (r 0.69, 95 % CI: 0.53, 0.79, P < 0.001) women; obese black (r 0.59, 95 % CI: 0.46, 0.70, P < 0.001) and white (r 0.56, 95 % CI: 0.30, 0.74, P < 0.001) women. NIR under-predicted BF% compared to DXA in black women (normal-weight, - 4.36 (sd 4.13) % and obese, - 3.41 (sd 3.72) %), while smaller mean differences were observed in white women (normal-weight, - 0.29 (sd 4.19) % and obese, - 0.81 (sd 3.09) %), irrespective of normal-weight or obese status (P < 0.001). In obese subjects, NIR-derived BF % did not measure values greater than approximately 45 %, while the maximum DXA-derived measure was 58 %. In conclusion, although there was a significant relationship between NIR- and DXA-derived BF %, NIR under-predicted BF % in normal-weight and obese black South African women compared to DXA, but to a greater extent in subjects with very high levels of adiposity (>45 %). The results of single-site NIR as a measure of BF % should therefore be interpreted with caution, particularly in women of African descent and in those with very high levels of adiposity.