Browsing by Author "Maredza, Alice"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
- ItemOpen AccessClinical diagnostic utility of IP-10 and LAM antigen levels for the diagnosis of tuberculous pleural effusions in a high burden setting(Public Library of Science, 2009) Dheda, Keertan; Van-Zyl Smit, Richard N; Sechi, Leonardo A; Badri, Motasim; Meldau, Richard; Symons, Gregory; Khalfey, Hoosein; Carr, Igshaan; Maredza, Alice; Dawson, RodneyBACKGROUND: Current tools for the diagnosis of tuberculosis pleural effusions are sub-optimal. Data about the value of new diagnostic technologies are limited, particularly, in high burden settings. Preliminary case control studies have identified IFN-γ-inducible-10kDa protein (IP-10) as a promising diagnostic marker; however, its diagnostic utility in a day-to-day clinical setting is unclear. Detection of LAM antigen has not previously been evaluated in pleural fluid. METHODS: We investigated the comparative diagnostic utility of established (adenosine deaminase [ADA]), more recent (standardized nucleic-acid-amplification-test [NAAT]) and newer technologies (a standardized LAM mycobacterial antigen-detection assay and IP-10 levels) for the evaluation of pleural effusions in 78 consecutively recruited South African tuberculosis suspects. All consenting participants underwent pleural biopsy unless contra-indicated or refused. The reference standard comprised culture positivity for M. tuberculosis or histology suggestive of tuberculosis. Principal FINDINGS: Of 74 evaluable subjects 48, 7 and 19 had definite, probable and non-TB, respectively. IP-10 levels were significantly higher in TB vs non-TB participants (p<0.0001). The respective outcomes [sensitivity, specificity, PPV, NPV %] for the different diagnostic modalities were: ADA at the 30 IU/L cut-point [96; 69; 90; 85], NAAT [6; 93; 67; 28], IP-10 at the 28,170 pg/ml ROC-derived cut-point [80; 82; 91; 64], and IP-10 at the 4035 pg/ml cut-point [100; 53; 83; 100]. Thus IP-10, using the ROC-derived cut-point, missed ∼20% of TB cases and mis-diagnosed ∼20% of non-TB cases. By contrast, when a lower cut-point was used a negative test excluded TB. The NAAT had a poor sensitivity but high specificity. LAM antigen-detection was not diagnostically useful. CONCLUSION: Although IP-10, like ADA, has sub-optimal specificity, it may be a clinically useful rule-out test for tuberculous pleural effusions. Larger multi-centric studies are now required to confirm our findings.
- ItemOpen AccessFeasibility and diagnostic utility of antigen-specific interferon-gamma responses for rapid immunodiagnosis of tuberculosis using induced sputum(Public Library of Science, 2010) Cashmore, Tamaryn J; Peter, Jonathan G; Van Zyl-Smit, Richard N; Semple, Patricia L; Maredza, Alice; Meldau, Richard; Zumla, Alimuddin; Nurse, Barbara; Dheda, KeertanBACKGROUND: The diagnosis of smear-negative or sputum-scarce tuberculosis (TB) is problematic as culture takes several weeks and representative biological samples are difficult to obtain. RD-1 antigen-specific interferon-γ release assays (IGRAs) are sensitive and specific blood-based tests for the diagnosis of M. tuberculosis infection. The feasibility and diagnostic utility of this rapid immunodiagnostic assay, using cells from induced sputum, is unknown. METHODOLOGY/PRINCIPAL FINDINGS: Cells isolated from induced sputum were co-cultured with ESAT-6 and CFP-10 antigens using a standardized enzyme-linked immunospot (ELISPOT) assay (T-SPOT®. TB ) in 101 consecutively recruited TB suspects or non-TB controls. An optimization phase using 28 samples was followed by a validation phase using samples from 73 participants (20 with definite or probable TB, and 48 with non-TB). Despite optimization of sputum processing 65/73 (89%) of the IGRAs in the validation phase were inconclusive. 44/73 (60%) tests failed due to sputum induction-related factors [sputum induction-related adverse events (n = 5), inadequate sputum volume (n = 8), non-homogenisable sputum (n = 7), and insufficient numbers of cells to perform the assay (n = 24)], whilst 20/73 (27%) tests failed due T-SPOT®. TB assay-related factors [excessive debris precluding reading of spots in the ELISPOT well (n = 6), failure of the positive control (n = 11), or high spot count in the negative control (n = 3)]. Only 8/73 (11%) of the available samples could therefore be correctly categorized (7 definite or probable TB, and 1 non-TB patient). Thus, 13/20 (65%) of the definite or probable TB cases remained undiagnosed. Conclusions/Significance: Rapid immunodiagnosis of pulmonary TB by antigen-specific IFN-γ ELISPOT responses, using cells from induced sputum, is possible. However, the test, in its current ELISPOT format, is not clinically useful because the majority of the assays are inconclusive.