A comparison of the Nickel and the conventional geothermometers with respect to the Jagersfontein and the Matsoku kimberlite peridotite xenolits

 

Show simple item record

dc.contributor.advisor Le Roux, A P en_ZA
dc.contributor.advisor Tredoux, M en_ZA
dc.contributor.author Mofokeng, Sipho Wiseman en_ZA
dc.date.accessioned 2014-11-16T20:01:31Z
dc.date.available 2014-11-16T20:01:31Z
dc.date.issued 1998 en_ZA
dc.identifier.citation Mofokeng, S. 1998. A comparison of the Nickel and the conventional geothermometers with respect to the Jagersfontein and the Matsoku kimberlite peridotite xenolits. University of Cape Town. en_ZA
dc.identifier.uri http://hdl.handle.net/11427/9683
dc.description Bibliography: leaves 116-125. en_ZA
dc.description.abstract The accuracy of the experimental (Canil, 1994; T-Canil) and the empirical (Ryan et al., 1996; T-Ryan) calibrations of the Ni geothermometer has been evaluated on two suites of geochemically and geothermobarometrically well characterised mantle xenoliths from Matsoku and Jagersfontein by comparison to the more commonly used conventional geothermometers. The two published calibrations of the Ni geothermometer are in agreement to within ±500C in the temperature range of ~900°C to 1200°C. Outside this temperature range, the two calibrations differ by between 75 and 150°C. The importance of the Ni geothermometer in diamond exploration and the studies of the mantle makes the resolution of this discrepancy very important. In addition to issues of calibration, errors in the determination of trace levels of Ni abundances in garnets may affect the accuracy of the Ni geothermometer. A 'reliable' Ni in garnet dataset was, therefore, required to minimise errors associated with Ni compositions used in temperature determination by Ni geothermometry. Thus, Ni compositions of garnets determined by PIXE, LA-ICP-MS and SIMS were compared to select the most 'reliable' dataset. Four matrix-matched secondary garnet standards were developed for the cross-checking and testing of the accuracy of data. The standards were developed by multi-method analyses, which included PIXE (using both the GeoPIXE and GUPIX software programmes for data reduction), LA-ICP-MS and solution ICP-MS. PIXE and LA-ICP-MS data were found to agree to within their 2σ errors of, respectively, 2 to 10% and 4 to 12% for a concentration range of ~15 to 112 ppm Ni. However, PIXE analyses were found to be superior in terms of smaller beam width, allowing several repeat analyses, and analysis of small and altered garnets thereby producing a relatively larger dataset. en_ZA
dc.language.iso eng en_ZA
dc.subject.other Geological Sciences en_ZA
dc.title A comparison of the Nickel and the conventional geothermometers with respect to the Jagersfontein and the Matsoku kimberlite peridotite xenolits en_ZA
dc.type Master Thesis
uct.type.publication Research en_ZA
uct.type.resource Thesis en_ZA
dc.publisher.institution University of Cape Town
dc.publisher.faculty Faculty of Science en_ZA
dc.publisher.department Department of Geological Sciences en_ZA
dc.type.qualificationlevel Masters
dc.type.qualificationname MSc en_ZA
uct.type.filetype Text
uct.type.filetype Image
dc.identifier.apacitation Mofokeng, S. W. (1998). <i>A comparison of the Nickel and the conventional geothermometers with respect to the Jagersfontein and the Matsoku kimberlite peridotite xenolits</i>. (Thesis). University of Cape Town ,Faculty of Science ,Department of Geological Sciences. Retrieved from http://hdl.handle.net/11427/9683 en_ZA
dc.identifier.chicagocitation Mofokeng, Sipho Wiseman. <i>"A comparison of the Nickel and the conventional geothermometers with respect to the Jagersfontein and the Matsoku kimberlite peridotite xenolits."</i> Thesis., University of Cape Town ,Faculty of Science ,Department of Geological Sciences, 1998. http://hdl.handle.net/11427/9683 en_ZA
dc.identifier.vancouvercitation Mofokeng SW. A comparison of the Nickel and the conventional geothermometers with respect to the Jagersfontein and the Matsoku kimberlite peridotite xenolits. [Thesis]. University of Cape Town ,Faculty of Science ,Department of Geological Sciences, 1998 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/9683 en_ZA
dc.identifier.ris TY - Thesis / Dissertation AU - Mofokeng, Sipho Wiseman AB - The accuracy of the experimental (Canil, 1994; T-Canil) and the empirical (Ryan et al., 1996; T-Ryan) calibrations of the Ni geothermometer has been evaluated on two suites of geochemically and geothermobarometrically well characterised mantle xenoliths from Matsoku and Jagersfontein by comparison to the more commonly used conventional geothermometers. The two published calibrations of the Ni geothermometer are in agreement to within ±500C in the temperature range of ~900°C to 1200°C. Outside this temperature range, the two calibrations differ by between 75 and 150°C. The importance of the Ni geothermometer in diamond exploration and the studies of the mantle makes the resolution of this discrepancy very important. In addition to issues of calibration, errors in the determination of trace levels of Ni abundances in garnets may affect the accuracy of the Ni geothermometer. A 'reliable' Ni in garnet dataset was, therefore, required to minimise errors associated with Ni compositions used in temperature determination by Ni geothermometry. Thus, Ni compositions of garnets determined by PIXE, LA-ICP-MS and SIMS were compared to select the most 'reliable' dataset. Four matrix-matched secondary garnet standards were developed for the cross-checking and testing of the accuracy of data. The standards were developed by multi-method analyses, which included PIXE (using both the GeoPIXE and GUPIX software programmes for data reduction), LA-ICP-MS and solution ICP-MS. PIXE and LA-ICP-MS data were found to agree to within their 2σ errors of, respectively, 2 to 10% and 4 to 12% for a concentration range of ~15 to 112 ppm Ni. However, PIXE analyses were found to be superior in terms of smaller beam width, allowing several repeat analyses, and analysis of small and altered garnets thereby producing a relatively larger dataset. DA - 1998 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 1998 T1 - A comparison of the Nickel and the conventional geothermometers with respect to the Jagersfontein and the Matsoku kimberlite peridotite xenolits TI - A comparison of the Nickel and the conventional geothermometers with respect to the Jagersfontein and the Matsoku kimberlite peridotite xenolits UR - http://hdl.handle.net/11427/9683 ER - en_ZA


Files in this item

This item appears in the following Collection(s)

Show simple item record