dc.description.abstract Mineral processing involves liberation and beneficiation operations. Several beneficiation processes exist and one such important process is froth flotation. The flotation process involves the transportation of valuable minerals of a hydrophobic nature into the froth and to the concentrate launder. This hydrophobicity may be natural or imparted by a collector. Froth structure is significant in determining the froth stability which has an effect on the grade and recovery of valuable minerals. The froth structure is dependent on amongst other factors the type of frothers used during the separation process. As a result, frother type and concentration can be used to manipulate the froth recovery and grade of valuable mineral recovered. Upper Group 2 (UG2) ore contains chromite minerals which are naturally hydrophilic. The chromite minerals are usually recovered in the concentrate mainly due to entrainment. This lowers the grade of valuable minerals recovered and poses detrimental effects to downstream operations. Thus, the froth structure plays an important role in the flotation performance of UG2 ore. This project was aimed at investigating the effect of chain length and functional group of different frothers on the froth stability, froth recovery and entrainment. Froth recovery, entrainment, solids and water recovery, as well as metallurgical recovery, were measured in a laboratory scale continuous column flotation cell. Froth stability was measured in a froth stability column, which is a non-overflowing column in which froth rise rate and equilibrium height were measured. A series of increasing molecular weight polyglycol and alcohol frothers, and their blends, were used to investigate the effect of frother type on froth structure. en_ZA
dc.language.iso eng en_ZA
dc.subject.other Chemical Engineering en_ZA
dc.title Investigating the effect of frother type on froth structure, froth recovery and entrainment en_ZA
dc.type Thesis / Dissertation en_ZA
uct.type.publication Research en_ZA
uct.type.resource Thesis en_ZA
dc.publisher.institution University of Cape Town
dc.publisher.faculty Faculty of Engineering & the Built Environment en_ZA
dc.publisher.department Department of Chemical Engineering en_ZA
dc.type.qualificationlevel Masters en_ZA
dc.type.qualificationname MSc (Eng) en_ZA
uct.type.filetype Text
uct.type.filetype Image


Files in this item

This item appears in the following Collection(s)

Show simple item record