Browsing by Author "Spottiswoode, Bruce S"
Now showing 1 - 4 of 4
Results Per Page
Sort Options
- ItemOpen Access3D cine DENSE MRI: ventricular segmentation and myocardial stratin analysis(2013) Auger, Daniel A; Spottiswoode, Bruce SIncludes abstract. Includes bibliographical references.
- ItemOpen AccessLong-Term Left Ventricular Remodelling in Rat Model of Nonreperfused Myocardial Infarction: Sequential MR Imaging Using a 3T Clinical Scanner(2012) Saleh, Muhammad G; Sharp, Sarah-Kate; Alhamud, Alkathafi; Spottiswoode, Bruce S; van der Kouwe, André J W; Davies, Neil H; Franz, Thomas; Meintjes, Ernesta MPurpose. To evaluate whether 3T clinical MRI with a small-animal coil and gradient-echo (GE) sequence could be used to characterize long-term left ventricular remodelling (LVR) following nonreperfused myocardial infarction (MI) using semi-automatic segmentation software (SASS) in a rat model. Materials and Methods. 5 healthy rats were used to validate left ventricular mass (LVM) measured by MRI with postmortem values. 5 sham and 7 infarcted rats were scanned at 2 and 4 weeks after surgery to allow for functional and structural analysis of the heart. Measurements included ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV), and LVM. Changes in different regions of the heart were quantified using wall thickness analyses. Results. LVM validation in healthy rats demonstrated high correlation between MR and postmortem values. Functional assessment at 4 weeks after MI revealed considerable reduction in EF, increases in ESV, EDV, and LVM, and contractile dysfunction in infarcted and noninfarcted regions. Conclusion. Clinical 3T MRI with a small animal coil and GE sequence generated images in a rat heart with adequate signal-to-noise ratio (SNR) for successful semiautomatic segmentation to accurately and rapidly evaluate long-term LVR after MI.
- ItemOpen AccessQuantifying right ventricular motion and strain using 3D cine DENSE MRI(BioMed Central Ltd, 2011) Auger, Daniel; Zhong, Xiaodong; Meintjes, Ernesta M; Epstein, Frederick H; Spottiswoode, Bruce SBackground: The RV is difficult to image because of its thin wall, asymmetric geometry and complex motion. DENSE is a quantitative MRI technique for measuring myocardial displacement and strain at high spatial and temporal resolutions [1,2]. DENSE encodes tissue displacement directly into the image phase, allowing for the direct extraction of motion data at a pixel resolution. A free-breathing navigator-gated spiral 3D cine DENSE sequence was recently developed [3], providing an MRI technique which is well suited to quantifying RV mechanics. Methods: Whole heart 3D cine DENSE data were acquired from two normal volunteers, after informed consent was obtained and in accordance with protocols approved by the University of Virginia institutional review board. The endocardial and epicardial contours were manually delineated to identify the myocardium from surrounding anatomical structures. A 3D spatiotemporal phase unwrapping algorithm was used to remove phase aliasing [4], and 3D Lagrangian displacement fields were derived for all cardiac phases. Midline contours were calculated from the epicardial and endocardial contours, and tissue tracking seed points were defined at pixel spaced intervals. A 3D tracking algorithm was implemented as a direct extension of the 2D tracking algorithm presented in [4], producing midline motion trajectories from which strain was calculated. Tangential 1D strain was calculated in the longitudinal and circumferential cardiac directions. Strain time curves are computed representing the free wall of the RV. Results: Figure 1 illustrates the RV free wall mean tangential 1D strain time curves for approximately 3/4 of the cardiac cycle over the apical-mid section of the heart for one volunteer. Results show measurements ranging between -0.1 and -0.25, and further illustrate a greater displacement in the longitudinal direction. Results compare favorably with studies using myocardial tagging and DENSE[5,6].
- ItemOpen AccessSemi-automated left ventricular segmentation based on a guide point model approach for 3D cine DENSE cardiovascular magnetic resonance(2014-01-14) Auger, Daniel A; Zhong, Xiaodong; Epstein, Frederick H; Meintjes, Ernesta M; Spottiswoode, Bruce SAbstract Background The most time consuming and limiting step in three dimensional (3D) cine displacement encoding with stimulated echoes (DENSE) MR image analysis is the demarcation of the left ventricle (LV) from its surrounding anatomical structures. The aim of this study is to implement a semi-automated segmentation algorithm for 3D cine DENSE CMR using a guide point model approach. Methods A 3D mathematical model is fitted to guide points which were interactively placed along the LV borders at a single time frame. An algorithm is presented to robustly propagate LV epicardial and endocardial surfaces of the model using the displacement information encoded in the phase images of DENSE data. The accuracy, precision and efficiency of the algorithm are tested. Results The model-defined contours show good accuracy when compared to the corresponding manually defined contours as similarity coefficients Dice and Jaccard consist of values above 0.7, while false positive and false negative measures show low percentage values. This is based on a measure of segmentation error on intra- and inter-observer spatial overlap variability. The segmentation algorithm offers a 10-fold reduction in the time required to identify LV epicardial and endocardial borders for a single 3D DENSE data set. Conclusion A semi-automated segmentation method has been developed for 3D cine DENSE CMR. The algorithm allows for contouring of the first cardiac frame where blood-myocardium contrast is almost nonexistent and reduces the time required to segment a 3D DENSE data set significantly.