• English
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Latviešu
  • Magyar
  • Nederlands
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Log In
  • Communities & Collections
  • Browse OpenUCT
  • English
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Latviešu
  • Magyar
  • Nederlands
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Log In
  1. Home
  2. Browse by Author

Browsing by Author "Dutkiewicz, R K"

Now showing 1 - 20 of 27
Results Per Page
Sort Options
  • Loading...
    Thumbnail Image
    Item
    Open Access
    An estimate of emissions from vehicles in South Africa
    (1993) Dutkiewicz, R K
  • Loading...
    Thumbnail Image
    Item
    Open Access
    Calibration of orifice plates with special emphasis on edge sharpness and eccentricity
    (1979) Lebi, Juliu; Dutkiewicz, R K
    A general review of the literature pertaining to flov1 measurement with orifice plates is presented. Special emphasis is laid on the factors influencing the coefficient of discharge Of orifice plates and. on the difference between the various engineering standards. Particular consideration is given to the effect on the discharge coefficient of rounding the upstream edge of the orifice plate and of changes in plate eccentricity. Various methods to calibrate orifice plates and to measure the edge roundness of orifice plates are discussed. Orifice plates with area ratios ranging from 0,1.to 0,55 were tested in order to evaluate variations in the coefficient of discharge with changes in: a) the upstream edge radius; b) the plate concentricity ty. The calibration tests were conducted with apparatus based on a system of weighing the working fluid which accumulates in a tank over an accurately determined time interval. In order to measure the upstream edge radius of an orifice plate, a lead foil holder was designed. Using the holder, accurate imprints of the edge profile were obtained in the lead foil. The apparatus used and the method of calibration is described in detail. Attention is drawn to the precautions required for accurate calibration. The method of calibration used was complicated by fluctuations in the differential pressure. It was found that the mean of twelve random pressure differential readings at a specific flow rate: did not vary by more than .f ·- o, 05 mm of mercury. Increasing the number of pressures
  • Loading...
    Thumbnail Image
    Item
    Open Access
    Cape Town brown haze study
    (1997) Wicking-Baird, M C; De Villiers, M G; Dutkiewicz, R K
  • Loading...
    Thumbnail Image
    Item
    Open Access
    Electricity saturation in South Africa
    (1991) Dutkiewicz, R K; Stoffeberg, T C
  • Loading...
    Thumbnail Image
    Item
    Open Access
    Electricity-economics relationship in South Africa
    (1992) Dutkiewicz, R K
  • Loading...
    Thumbnail Image
    Item
    Open Access
    Energy demand elasticities in South Africa
    (1987) Pouris, A; Dutkiewicz, R K
  • Loading...
    Thumbnail Image
    Item
    Open Access
    Energy efficiency indicators for South Africa
    (1993) Dutkiewicz, R K
  • Loading...
    Thumbnail Image
    Item
    Open Access
    Energy efficiency of non-face brick production with particular reference to the drying process
    (1993) de la Hunt, Herbert William Garnet; Dutkiewicz, R K
    Energy inefficiencies are at present a characteristic of the Heavy Clay Industry throughout the world. In the Western Cape there has been a marked trend towards the use of unsophisticated plant for the manufacture of non-face plaster bricks since the nineteen sixties. At present all non-face plaster bricks are fired in clamps and only a few factories use dryers. Hollow ware rather than solid bricks find favour in South America, Asia and Europe, with the exceptions of the United Kingdom and the Netherlands, (the Netherlands use the soft mud process which does not lend itself to hollow ware production). However, in South Africa, in spite of potential energy and clay saving, the number of hollow block factories, has shrunk in the past 30 years. The only move towards hollow ware, has been the perforation, of face bricks. In the Western Cape no factories perforate their non-face bricks. The reduced production and cartage costs, could be passed on to the builder. Other advantages for low-cost housing are easier bricklaying, as well the aesthetic appeal of clay for semi-face finishes. Of considerable concern, to the Heavy Clay Industry is the fact that the energy and clay saving, as well as the reduced cartage cost, allows the clay hollow block to be competitive against cement, it's major rival in the field of "affordable housing". The hollow block, although larger, can be lighter than the solid brick, and has the further advantages of less units per square metre "in the wall", as well as good insulating properties. To produce hollow ware in the Western Cape, without major plant changes, it was necessary to test the possibility of firing hollow ware in clamps. This was achieved for the conventional non-face brick size and the maxi brick, both made with transverse holes. The purpose of this study was to provide an efficient method of drying bricks, particularly for factories which were drying in the open air. The hollow ware possibility widened the scope of the study, and a dryer was designed to dry both hollow ware and solid bricks. A constraint on the dryer design was the basic premise that the dryer would ultimately form part of an integrated dryer/kiln system. Open air drying in the Western Cape, while requiring no additional heat or electrical energy, does use forklifts, which use diesel and are expensive. The open air drying process has a high waste component and is weather dependent. Heavy losses have been experienced, not only during the autumn and spring, but often even in the middle of summer, due to unseasonal downpours. Arguably the main area of concern, to the producer, is the inefficient use of plant and labour during the winter months. The costs, to the producer, of the open air drying process were established. The literature survey dealt with the basic principles and problems of drying heavy clay products, as well as innovations and engineering problems in the field of drying. Initial tests were done on a test unit, large enough to simulate plant conditions. From the results of these tests, the work covered in the literature, as well as past practical plant experience, sufficient information was available to build a prototype plant dryer. The prototype dryer was constructed to dry units standing "one-high, soldier". With this setting, and the proposed airflow, it is possible to treat each unit in exactly the same manner as its neighbour. In this way it is possible to obtain results comparable to those obtained under laboratory conditions and achieve fast drying times. Fast drying implies a relatively small dryer with minimum heat losses, as well as having good control. The "One-high" configuration lends itself to simple setting and off-loading mechanisms. An objective of this study was to minimise the capital investment. The value of the waste saving, on open air drying, over two years, was regarded as an arbitrary amount to aim for, as the cost of the dryer. In fact, the dryer was built at below the capital cost of the forklifts which were eliminated by changing the drying method. Pallets were eliminated, as was the need for setting labour. Fast drying of the order of 1-3 hours implies that the dryer is, in a sense, an extension of the extrusion process. The dryer can be switched on and off with the extruder, but what is more important is the fact that a plant which normally operates only on day shift, can be operated on a 24 hour basis without the need to build extra drying facilities. This latter point is of considerable importance in building boom periods. Clamps do not generate recoverable waste heat for drying. Phase two of this project will be to design the kiln, which is compatible, in concept, with the dryer. The proposed kiln will operate with less specific energy than clamps and generate the heat required to dry the bricks. In conclusion, the study leaves the fine tuning of the dryer for energy efficiency, still to be completed. In spite of this the dryer satisfies all the proposed conceptual criteria. It will be able to operate on the waste hot air from the kiln. If the kiln can operate at the level of the best commercial kilns at present available, and yet be built for a capital amount of the same order as the dryer, then an attractive alternative to clamp firing will have been found. Because the recoverable heat from the kiln is available, irrespective of the drying process, there will be no specific energy drying cost, the same situation that applies with open air drying, but, with none of its attendant problems.
  • Loading...
    Thumbnail Image
    Item
    Open Access
    Energy in South Africa: A policy discussion document
    (1994) Dutkiewicz, R K
  • Loading...
    Thumbnail Image
    Item
    Open Access
    Energy modelling in the South African electric power industry
    (1977) Ben-Yaacov, Giora Zeev; Dutkiewicz, R K
    The subject of this thesis is the development of a modelling system for the planning of the South African electricity supply industry. A power system planning process was developed with the object of ~stablishing a long-range development plan that would enable the selection and timing of individual projects. This planning process is represented by several sub-models which include the prediction of future demands, the assessment of the generating capacity and the proportions of the different types of generating plant on the system (the plant "mix"), the analysis of the transmission network performances and the simulation of the financial processes. One of the characteristics of the modelling system presented is its three-stage structure. The first stage is represented by the load model for the long-term prediction of power and energy demand. The second stage is represented by the two expansion models for generation and transmission. With the aid of these two models several expansion strategies are pre-selected, and then in the third stage, using the financial model, the total capital requirements are established. The future system demand is predicted from the analysis of historical data and by the formulation of the electricity - and economic growth relationship: Two major calculations, linear programming optimisation and loss of load probability analysis, are used in the computer models which aid the policy makers in selecting the optimum size and mix of the generating plants and scheduling the operation and maintenance of the generating units. Transmission system analysis programs have been developed in such a way that they use a common power system data base which enables the planning engineers to store and maintain their power system data. The calculation routines include load flow, fault analysis, stability studies, single and three phase travelling. Waves, and power and high ii frequency transmission line parameters. The costing and financial models include the analysis of costs of all new expansion equipment, the costs of operation and maintenance of the generation units, transmission equipment and fuel, and the simulation of the financial environment and accounting processes. On the basis of experience gained so far, the author arrives at the conclusion that the modelling system presented is capable of providing a useful tool for planning the expansion of the South African electricity supply industry .
  • Loading...
    Thumbnail Image
    Item
    Open Access
    Energy profile: Ethiopia
    (1993) Gielink, M I; Dutkiewicz, R K
  • Loading...
    Thumbnail Image
    Item
    Open Access
    Energy profile: Lesotho
    (1991) Gielink, M I; Dutkiewicz, R K
    This report is one of a series summarizing the energy situation in sub-equatorial Africa. The purpose of the series is to analyze the energy position for those organizations trading or intending to trade with those countries, or for organizations entering into joint ventures with those countries. It is also the intention to use the individual reports to determine the possibility for energy interchange in the region and the potential for energy supply and demand in the region.
  • Loading...
    Thumbnail Image
    Item
    Open Access
    Energy profile: Lesotho
    (1991) Gielink, M I; Dutkiewicz, R K
  • Loading...
    Thumbnail Image
    Item
    Open Access
    Energy profile: Malawi
    (1992) Gielink, M I; Dutkiewicz, R K
  • Loading...
    Thumbnail Image
    Item
    Open Access
    Energy profile: Mozambique
    (1991) Dutkiewicz, R K; Gielink, M I
  • Loading...
    Thumbnail Image
    Item
    Open Access
    Energy profile: South Africa
    (1993) Gielink, M I; Dutkiewicz, R K
  • Loading...
    Thumbnail Image
    Item
    Open Access
    Energy profile: Swaziland
    (1992) Gielink, M I; Dutkiewicz, R K
  • Loading...
    Thumbnail Image
    Item
    Open Access
    Energy profile: Tanzania
    (1991) Gielink, M I; Dutkiewicz, R K
  • Loading...
    Thumbnail Image
    Item
    Open Access
    Energy profile: Zaire
    (1990) Dutkiewicz, R K
  • Loading...
    Thumbnail Image
    Item
    Open Access
    Energy profile: Zambia
    (1991) Dutkiewicz, R K
  • «
  • 1 (current)
  • 2
  • »
UCT Libraries logo

Contact us

Jill Claassen

Manager: Scholarly Communication & Publishing

Email: openuct@uct.ac.za

+27 (0)21 650 1263

  • Open Access @ UCT

    • OpenUCT LibGuide
    • Open Access Policy
    • Open Scholarship at UCT
    • OpenUCT FAQs
  • UCT Publishing Platforms

    • UCT Open Access Journals
    • UCT Open Access Monographs
    • UCT Press Open Access Books
    • Zivahub - Open Data UCT
  • Site Usage

    • Cookie settings
    • Privacy policy
    • End User Agreement
    • Send Feedback

DSpace software copyright © 2002-2025 LYRASIS