- ItemOpen AccessPD trending and TVA test readings are good indicators of the condition of aged stator bar insulation.(2012) Bruintjies, Mark Anthony; Gaunt, C TrevorKeeping generators available on-line is a major factor in achieving maximum productivity in power generation. During operation, generator components are continuously exposed to thermal, electrical, mechanical and environmental stresses. The complex interactions of these stresses degrade the components resulting in a reduction of useful life. An integral part of satisfactory operation of high voltage (HV) electrical rotating plant relies upon the integrity of the electrical HV insulation of both the rotor and stator. The combined effect of the above mentioned stresses results in ageing of the insulation, which if not detected, results in premature failure in service. Deterioration of the stator bar insulation is a leading factor for determining the serviceability of hydro generators. Unexpected and expected stator bar failure can result in forced outages and costly emergency repairs. This research will deal with the deterioration of stator bar insulation in air-cooled hydro generators only.
- ItemOpen AccessTesting for relationship between diagnostic tests and DC BDV of in-serviced aged stator bars of a hydro generator(2024) Bruintjies, Mark Anthony; Gaunt, Trevor ; Barendse, PaulThe effective management of assets currently presents a challenge to utilities. A cognisance and understanding of the actual condition of these assets will enable utilities to implement mitigation strategies and use these assets for the full duration of their lifespan. One of these assets could be hydro generators with the stator bars constituting one of the failing components. Integral to the satisfactory operation of a high voltage (HV) electrical rotating plant is the integrity of the electrical high voltage insulation of both the rotor and stator. During operation, high voltage generator components (for example stator bars), are continuously and simultaneously subjected to electrical, thermal, mechanical and ambient (environment) stresses. Subsequently, the complex interactions of these stresses degrade and deteriorate the insulation material gradually, resulting in a reduction of valuable operative life, potential forced outages and costly emergency repairs. Because both expected and unexpected stator bar in-service failures may lead to costly repairs, rotating machine users implement condition monitoring (CM), diagnostic tests and condition-based maintenance in order to mitigate risk. The contribution was executed in the form of removing aged stator bars from a generator and subjecting the bars to various diagnostic and direct current (DC) HV tests, testing for correlation. The diagnostic tests included insulation resistance (IR), polarization index (PI), partial discharge (PD), tan delta (TD) and Tennessee Valley Authority (TVA) tests. The HV breakdown tests included very low frequency (VLF) and DC tests. Despite using this wider range of tests than has been used before, the test results still confirm earlier reports that there are no clear correlations between the different diagnostic tests. There is also no clear relationship between the condition monitoring test results and physical breakdown of the insulation in the high voltage tests. Hence, it was concluded that these diagnostic tests on their own could not predict incipient insulation failure and that currently the most value derived from these tests would be to use the results as trending parameters rather than absolute values to predict insulation failure.