Interlandmark measurements from lodox statscan images with application to femoral neck anteversion assessment

Master Thesis

2013

Permanent link to this Item
Authors
Supervisors
Journal Title
Link to Journal
Journal ISSN
Volume Title
Publisher
Publisher

University of Cape Town

License
Series
Abstract
Clinicians often take measurements between anatomical landmarks on X-ray radiographs for diagnosis and treatment planning, for example in orthopaedics and orthodontics. X-ray images, however, overlap three-dimensional internal structures onto a two-dimensional plane during image formation. Depth information is therefore lost and measurements do not truly reflect spatial relationships. The main aim of this study was to develop an inter-landmark measurement tool for the Lodox Statscan digital radiography system. X-ray stereophotogrammetry was applied to Statscan images to enable three-dimensional point localization for inter-landmark measurement using two-dimensional radiographs. This technique requires images of the anatomical region of interest to be acquired from different perspectives as well as a suitable calibration tool to map image coordinates to real world coordinates. The Statscan is suited to the technique because it is capable of axial rotations for multiview imaging. Three-dimensional coordinate reconstruction and inter-landmark measurements were taken using a planar object and a dry pelvis specimen in order to assess the intra-observer measurement accuracy, reliability and precision. The system yielded average (X, Y, Z) coordinate reconstruction accuracy of (0.08 0.12 0.34) mm and resultant coordinate reconstruction accuracy within 0.4mm (range 0.3mm – 0.6mm). Inter-landmark measurements within 2mm for lengths and 1.80 for angles were obtained, with average accuracies of 0.4mm (range 0.0mm – 2.0 mm) and 0.30 (range 0.0 – 1.8)0 respectively. The results also showed excellent overall precision of (0.5mm, 0.10) and were highly reliable when all landmarks were completely visible in both images. Femoral neck anteversion measurement on Statscan images was also explored using 30 dry right adult femurs. This was done in order to assess the feasibility of the algorithm for a clinical application. For this investigation, four methods were tested to determine the optimal landmarks for measurement and the measurement process involved calculation of virtual landmarks. The method that yielded the best results produced all measurements within 10 of reference values and the measurements were highly reliable with very good precision within 0.10. The average accuracy was within 0.40 (range 0.10 –0.80).In conclusion, X-ray stereophotogrammetry enables accurate, reliable and precise inter-landmark measurements for the Lodox Statscan X-ray imaging system. The machine may therefore be used as an inter-landmark measurement tool for routine clinical applications.
Description

Includes abstract.


Includes bibliographical references.

Reference:

Collections